{"product_id":"armstrong-air-d504233-armstrong-880t-inverted-thermic-bucket-trap-w-strainer-1-2-npt-20-psi-3-16-orifice","title":"Armstrong Air D504233 Armstrong 880T Inverted Thermic Bucket Trap w\/ Strainer 1\/2 NPT 20 PSI 3\/16 Orifice - D504233","description":"\u003ch2\u003eArmstrong Air D504233 Armstrong 880T Inverted Thermic Bucket Trap w\/ Strainer 1\/2 NPT 20 PSI 3\/16 Orifice - D504233\u003c\/h2\u003e\n\u003cp\u003eThe Armstrong 880T inverted bucket steam trap, model D504233, is engineered to improve steam system efficiency. Constructed with durable cast iron, this unit features a 1\/2 inch NPT in-line horizontal connection.\u003c\/p\u003e\n\u003cp\u003eThe design employs a simple leverage system, using the bucket’s weight to operate the valve against steam pressure, enhancing reliability and longevity. This steam trap is particularly suitable for heat exchange equipment, noted for its quick air venting and non-condensable gas handling capabilities.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMax operating pressure of 20 psi.\u003c\/li\u003e\n\u003cli\u003eEffective condensate discharge capacity up to 690 pounds per hour.\u003c\/li\u003e\n\u003cli\u003eIncorporates an integral strainer and thermic bucket for optimized performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e Specifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-ij4v{background-color:#ffffff;color:#000000;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-ij4v\"\u003eConnection Size\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003e1\/2 inch NPT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eIn-Line Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eMax Pressure\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e20 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eOrifice Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3\/16 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e5.50 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eArmstrong International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eMPN\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eD504233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e880 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ij4v\"\u003eBody Material\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Expect Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"30\" data-end=\"141\"\u003e\n\u003cstrong data-start=\"32\" data-end=\"59\"\u003eEfficient Steam Control\u003c\/strong\u003e: Inverted thermic bucket design ensures optimal steam flow and trap efficiency.\u003c\/li\u003e\n\u003cli data-start=\"142\" data-end=\"267\"\u003e\n\u003cstrong data-start=\"144\" data-end=\"172\"\u003eHigh-Pressure Capability\u003c\/strong\u003e: Rated for up to 20 PSI, making it ideal for residential and light commercial steam systems.\u003c\/li\u003e\n\u003cli data-start=\"268\" data-end=\"384\"\u003e\n\u003cstrong data-start=\"270\" data-end=\"294\"\u003eDurable Construction\u003c\/strong\u003e: Built with high-quality materials, including a strainer, for long-lasting reliability.\u003c\/li\u003e\n\u003cli data-start=\"385\" data-end=\"513\"\u003e\n\u003cstrong data-start=\"387\" data-end=\"408\"\u003ePrecise Operation\u003c\/strong\u003e: 3\/16-inch orifice provides effective air and condensate management for consistent system performance.\u003c\/li\u003e\n\u003cli data-start=\"514\" data-end=\"624\"\u003e\n\u003cstrong data-start=\"516\" data-end=\"537\"\u003eEasy Installation\u003c\/strong\u003e: 1\/2-inch NPT threading allows for seamless integration into existing steam systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"141\" data-end=\"390\"\u003e\u003cstrong data-start=\"141\" data-end=\"211\"\u003eQ: is the Armstrong Air D504233 Inverted Thermic Bucket Trap?\u003c\/strong\u003e\u003cbr data-start=\"211\" data-end=\"214\"\u003eA: The D504233 is a 1\/2 NPT inverted thermic bucket steam trap with a built-in strainer, designed to efficiently remove condensate from steam systems while operating at 20 PSI.\u003c\/p\u003e\n\u003cp data-start=\"623\" data-end=\"808\"\u003e\u003cstrong data-start=\"623\" data-end=\"680\"\u003eQ: Is this steam trap suitable for all steam systems?\u003c\/strong\u003e\u003cbr data-start=\"680\" data-end=\"683\"\u003eA: The D504233 is ideal for various steam applications, but ensure compatibility with your specific system before purchasing.\u003c\/p\u003e\n\u003cp data-start=\"810\" data-end=\"1020\"\u003e\u003cstrong data-start=\"810\" data-end=\"872\"\u003eQ: How does the thermic bucket design improve performance?\u003c\/strong\u003e\u003cbr data-start=\"872\" data-end=\"875\"\u003eA: The inverted thermic bucket design efficiently removes condensate while preventing water hammer, improving system reliability and performance.\u003c\/p\u003e\n\u003cp data-start=\"1022\" data-end=\"1180\"\u003e\u003cstrong data-start=\"1022\" data-end=\"1071\"\u003eQ: Does it require professional installation?\u003c\/strong\u003e\u003cbr data-start=\"1071\" data-end=\"1074\"\u003eA: Yes, professional installation is recommended for proper setup and to ensure optimal system efficiency.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"147\" data-end=\"271\"\u003e\n\u003cstrong data-start=\"150\" data-end=\"171\"\u003eInspect for Leaks\u003c\/strong\u003e – Regularly check the trap for steam or fluid leaks around the connections to ensure a secure seal.\u003c\/li\u003e\n\u003cli data-start=\"272\" data-end=\"406\"\u003e\n\u003cstrong data-start=\"275\" data-end=\"297\"\u003eClean the Strainer\u003c\/strong\u003e – Periodically remove the strainer to clean debris and dirt that could block the flow and reduce efficiency.\u003c\/li\u003e\n\u003cli data-start=\"407\" data-end=\"568\"\u003e\n\u003cstrong data-start=\"410\" data-end=\"438\"\u003eCheck the Thermic Bucket\u003c\/strong\u003e – Inspect the inverted thermic bucket for proper operation, ensuring it moves freely and doesn’t have signs of corrosion or wear.\u003c\/li\u003e\n\u003cli data-start=\"569\" data-end=\"693\"\u003e\n\u003cstrong data-start=\"572\" data-end=\"592\"\u003eMonitor Pressure\u003c\/strong\u003e – Ensure the trap operates within the 20 PSI rating to avoid over-pressurization and prevent damage.\u003c\/li\u003e\n\u003cli data-start=\"694\" data-end=\"809\"\u003e\n\u003cstrong data-start=\"697\" data-end=\"719\"\u003eVerify the Orifice\u003c\/strong\u003e – Check the 3\/16-inch orifice for any obstructions that could hinder steam or fluid flow.\u003c\/li\u003e\n\u003cli data-start=\"810\" data-end=\"963\"\u003e\n\u003cstrong data-start=\"813\" data-end=\"839\"\u003eEnsure Proper Drainage\u003c\/strong\u003e – Confirm that the trap’s drainage is functioning correctly to prevent water accumulation and maintain efficient operation.\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1120\"\u003e\n\u003cstrong data-start=\"967\" data-end=\"1001\"\u003eAnnual Professional Inspection\u003c\/strong\u003e – Have a technician inspect the trap annually to ensure it's functioning properly and to address any potential issues.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Armstrong Air","offers":[{"title":"Default Title","offer_id":46383714959585,"sku":"D504233","price":356.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/171213192.jpg?v=1746037005","url":"https:\/\/sportsteez.com\/products\/armstrong-air-d504233-armstrong-880t-inverted-thermic-bucket-trap-w-strainer-1-2-npt-20-psi-3-16-orifice","provider":"EP","version":"1.0","type":"link"}