{"product_id":"armstrong-fluid-technology-e9-2-120v-ci-flanged-pump","title":"Armstrong Flanged Circulation Pump E9 Series 1\/6 hp 120 VAC - 182202-659","description":"\u003ch2\u003eArmstrong Flanged Circulation Pump E9 Series 1\/6 hp 120 VAC - 182202-659\u003c\/h2\u003e\n\u003cp\u003eThe Armstrong Flanged Circulation Pump E9 Series, model 182202-659, is suitable for various hydronic applications such as heating and cooling systems. Its design emphasizes energy efficiency, making it an optimal choice for residential and light commercial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Armstrong Flanged Circulation Pump E9 Series, model 182202-659, is suitable for various hydronic applications such as heating and cooling systems. Its design emphasizes energy efficiency, making it an optimal choice for residential and light commercial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHigh efficiency circulator, 120V\u003c\/li\u003e\n\u003cli\u003eCompact motor design, 30% smaller than traditional models\u003c\/li\u003e\n\u003cli\u003eDurable with field-repairable mechanical seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eHP Rating\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003e1\/6 hp\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFlow Rate\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e38 gpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaximum Head\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e42.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFrequency Rating\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e14.09 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e7.1 in W x 6.4 in H x 4.2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eImpeller Material\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e30% Glass-Filled Noryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eTemperature Rating\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e32 - 230 deg F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePressure Rating\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e150 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eRPM\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eArmstrong\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"290\" data-start=\"166\"\u003e\n\u003cstrong data-end=\"184\" data-start=\"168\"\u003e1\/6 HP Motor\u003c\/strong\u003e – Provides sufficient power for a variety of circulating applications while ensuring energy efficiency.\u003c\/li\u003e\n\u003cli data-end=\"399\" data-start=\"291\"\u003e\n\u003cstrong data-end=\"310\" data-start=\"293\"\u003e120 VAC Power\u003c\/strong\u003e – Compatible with standard voltage, making it easy to integrate into existing systems.\u003c\/li\u003e\n\u003cli data-end=\"509\" data-start=\"400\"\u003e\n\u003cstrong data-end=\"424\" data-start=\"402\"\u003eFlanged Connection\u003c\/strong\u003e – Offers a secure and leak-free connection, ensuring optimal flow and performance.\u003c\/li\u003e\n\u003cli data-end=\"642\" data-start=\"510\"\u003e\n\u003cstrong data-end=\"536\" data-start=\"512\"\u003eDurable Construction\u003c\/strong\u003e – Built to withstand harsh conditions, offering long-lasting reliability and reduced maintenance needs.\u003c\/li\u003e\n\u003cli data-end=\"810\" data-start=\"643\"\u003e\n\u003cstrong data-end=\"670\" data-start=\"645\"\u003eVersatile Application\u003c\/strong\u003e – Ideal for heating, cooling, and HVAC systems, this pump is designed to meet the demands of both commercial and industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-end=\"370\" data-start=\"86\"\u003e\u003cstrong data-end=\"152\" data-start=\"86\"\u003eQ: What is the Armstrong 182202-659 circulation pump used for?\u003c\/strong\u003e\u003cbr data-end=\"155\" data-start=\"152\"\u003eA: The Armstrong 182202-659 is a flanged circulation pump designed to efficiently circulate fluids in heating, cooling, and other fluid transfer systems. It's ideal for residential and light commercial applications.\u003c\/p\u003e\n\u003cp data-end=\"890\" data-start=\"628\"\u003e\u003cstrong data-end=\"696\" data-start=\"628\"\u003eQ: What makes the Armstrong 182202-659 pump ideal for my system?\u003c\/strong\u003e\u003cbr data-end=\"699\" data-start=\"696\"\u003eA: The 182202-659 pump provides efficient, consistent circulation while maintaining a compact design. It's perfect for systems that require reliable fluid movement with low power consumption.\u003c\/p\u003e\n\u003cp data-end=\"1151\" data-start=\"892\"\u003e\u003cstrong data-end=\"960\" data-start=\"892\"\u003eQ: How does the Armstrong 182202-659 improve system performance?\u003c\/strong\u003e\u003cbr data-end=\"963\" data-start=\"960\"\u003eA: By offering steady fluid circulation, this pump ensures optimal performance of heating and cooling systems, reducing the risk of overheating and ensuring consistent system temperatures.\u003c\/p\u003e\n\u003cp data-end=\"1374\" data-start=\"1153\"\u003e\u003cstrong data-end=\"1213\" data-start=\"1153\"\u003eQ: Is the Armstrong 182202-659 circulation pump durable?\u003c\/strong\u003e\u003cbr data-end=\"1216\" data-start=\"1213\"\u003eA: Yes, built with high-quality materials, this pump is designed for long-lasting performance and reliability in both residential and commercial applications.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"221\" data-start=\"99\"\u003e\n\u003cstrong data-end=\"123\" data-start=\"102\"\u003eInspect for Leaks\u003c\/strong\u003e – Regularly check all connections, seals, and flanges for leaks and tighten any loose fittings.\u003c\/li\u003e\n\u003cli data-end=\"365\" data-start=\"222\"\u003e\n\u003cstrong data-end=\"254\" data-start=\"225\"\u003eMonitor Motor Performance\u003c\/strong\u003e – Listen for unusual noises or vibrations indicating a motor issue and ensure the motor is running smoothly.\u003c\/li\u003e\n\u003cli data-end=\"500\" data-start=\"366\"\u003e\n\u003cstrong data-end=\"394\" data-start=\"369\"\u003eCheck for Overheating\u003c\/strong\u003e – Monitor pump temperature to avoid overheating, which could cause motor failure or reduced efficiency.\u003c\/li\u003e\n\u003cli data-end=\"646\" data-start=\"501\"\u003e\n\u003cstrong data-end=\"535\" data-start=\"504\"\u003eClean the Pump and Impeller\u003c\/strong\u003e – Periodically clean the pump and impeller to prevent debris buildup and ensure efficient fluid circulation.\u003c\/li\u003e\n\u003cli data-end=\"766\" data-start=\"647\"\u003e\n\u003cstrong data-end=\"672\" data-start=\"650\"\u003eLubricate Bearings\u003c\/strong\u003e – Lubricate the bearings as needed to reduce friction and prolong the lifespan of the pump.\u003c\/li\u003e\n\u003cli data-end=\"912\" data-start=\"767\"\u003e\n\u003cstrong data-end=\"797\" data-start=\"770\"\u003eTest the Pump Regularly\u003c\/strong\u003e – Perform routine performance checks to confirm the pump is circulating fluid as expected without interruptions.\u003c\/li\u003e\n\u003cli data-end=\"1029\" data-start=\"913\"\u003e\n\u003cstrong data-end=\"949\" data-start=\"916\"\u003eInspect Electrical Components\u003c\/strong\u003e – Periodically check the power supply and wiring for signs of wear or damage.\u003c\/li\u003e\n\u003cli data-end=\"1145\" data-start=\"1030\"\u003e\n\u003cstrong data-end=\"1052\" data-start=\"1033\"\u003eReplace Filters\u003c\/strong\u003e – If your system uses filters, replace them regularly to ensure uninterrupted performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Armstrong Air","offers":[{"title":"Default Title","offer_id":46383709585633,"sku":"182202-659","price":572.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/172261492.jpg?v=1746036663","url":"https:\/\/sportsteez.com\/products\/armstrong-fluid-technology-e9-2-120v-ci-flanged-pump","provider":"EP","version":"1.0","type":"link"}