{"product_id":"armstrong-international-c5297-50-880-series-1-2-in-450f-250-psi-steam-trap","title":"Armstrong International 880 Series 1\/2 in. 450F 250 psi Steam Trap - C5297-50","description":"\u003ch2\u003eArmstrong International 880 Series 1\/2 in. 450F 250 psi Steam Trap - C5297-50\u003c\/h2\u003e\n\u003cp\u003eThe Armstrong International C5297-50 880 Series steam trap is designed for high-pressure steam systems. It operates effectively under pressures up to 250 psi, delivering a maximum capacity of four thousand four hundred pounds per hour. This steam trap is constructed from durable cast iron, suitable for horizontal installation.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Armstrong International C5297-50 880 Series steam trap is designed for high-pressure steam systems. It operates effectively under pressures up to 250 psi, delivering a maximum capacity of four thousand four hundred pounds per hour. This steam trap is constructed from durable cast iron, suitable for horizontal installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFor application with steam systems\u003c\/li\u003e\n\u003cli\u003eInverted bucket design for efficient condensate drainage\u003c\/li\u003e\n\u003cli\u003eRepairable for enhanced maintenance savings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003ePart Number\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eC5297-50\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eArmstrong International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e250 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCapacity\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e4400 lb\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInlet Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eInverted Bucket with Integral Strainer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cbr\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"185\" data-end=\"317\"\u003e\n\u003cstrong data-start=\"187\" data-end=\"229\"\u003eHigh Temperature \u0026amp; Pressure Resistance\u003c\/strong\u003e – Handles up to 450°F and 250 PSI, ideal for demanding industrial steam applications.\u003c\/li\u003e\n\u003cli data-start=\"318\" data-end=\"400\"\u003e\n\u003cstrong data-start=\"320\" data-end=\"343\"\u003e1\/2\" NPT Connection\u003c\/strong\u003e – Standard size for easy integration with your system.\u003c\/li\u003e\n\u003cli data-start=\"401\" data-end=\"530\"\u003e\n\u003cstrong data-start=\"403\" data-end=\"435\"\u003eEfficient Condensate Removal\u003c\/strong\u003e – Ensures optimal condensate management, improving system performance and energy efficiency.\u003c\/li\u003e\n\u003cli data-start=\"531\" data-end=\"639\"\u003e\n\u003cstrong data-start=\"533\" data-end=\"557\"\u003eDurable Construction\u003c\/strong\u003e – Built to withstand the toughest environments, offering long-term reliability.\u003c\/li\u003e\n\u003cli data-start=\"640\" data-end=\"767\"\u003e\n\u003cstrong data-start=\"642\" data-end=\"672\"\u003eDesigned for Steam Systems\u003c\/strong\u003e – Ideal for industrial processes requiring precise steam control and consistent performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"93\" data-end=\"332\"\u003e\u003cstrong data-start=\"93\" data-end=\"151\"\u003eQ: What is the Armstrong C5297-50 steam trap used for?\u003c\/strong\u003e\u003cbr data-start=\"151\" data-end=\"154\"\u003eA: The Armstrong C5297-50 steam trap is designed to remove condensate from steam systems while preventing steam loss, improving energy efficiency in high-pressure applications.\u003c\/p\u003e\n\u003cp data-start=\"597\" data-end=\"817\"\u003e\u003cstrong data-start=\"597\" data-end=\"663\"\u003eQ: What types of applications is this steam trap suitable for?\u003c\/strong\u003e\u003cbr data-start=\"663\" data-end=\"666\"\u003eA: Perfect for use in industrial heating systems, heat exchangers, and other high-pressure steam applications requiring efficient condensate removal.\u003c\/p\u003e\n\u003cp data-start=\"819\" data-end=\"1058\"\u003e\u003cstrong data-start=\"819\" data-end=\"895\"\u003eQ: How does the Armstrong C5297-50 steam trap improve system efficiency?\u003c\/strong\u003e\u003cbr data-start=\"895\" data-end=\"898\"\u003eA: By efficiently removing condensate, it ensures that steam is not wasted, preventing energy loss and improving the overall performance of your steam system.\u003c\/p\u003e\n\u003cp data-start=\"1060\" data-end=\"1257\"\u003e\u003cstrong data-start=\"1060\" data-end=\"1112\"\u003eQ: Is the Armstrong C5297-50 steam trap durable?\u003c\/strong\u003e\u003cbr data-start=\"1112\" data-end=\"1115\"\u003eA: Yes, it is built with durable materials to provide long-lasting, reliable performance in high-pressure and high-temperature environments.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"106\" data-end=\"218\"\u003e\n\u003cstrong data-start=\"109\" data-end=\"128\"\u003eCheck for Leaks\u003c\/strong\u003e – Regularly inspect the steam trap for leaks, especially around joints and connections.\u003c\/li\u003e\n\u003cli data-start=\"219\" data-end=\"335\"\u003e\n\u003cstrong data-start=\"222\" data-end=\"244\"\u003eClean the Strainer\u003c\/strong\u003e – Clean the internal strainer to prevent debris buildup that could obstruct proper flow.\u003c\/li\u003e\n\u003cli data-start=\"336\" data-end=\"481\"\u003e\n\u003cstrong data-start=\"339\" data-end=\"373\"\u003eMonitor Temperature \u0026amp; Pressure\u003c\/strong\u003e – Ensure the steam trap operates within the recommended 250 psi and 450°F limits for optimal performance.\u003c\/li\u003e\n\u003cli data-start=\"482\" data-end=\"598\"\u003e\n\u003cstrong data-start=\"485\" data-end=\"510\"\u003eInspect for Corrosion\u003c\/strong\u003e – Regularly check for any signs of corrosion or damage that may impact functionality.\u003c\/li\u003e\n\u003cli data-start=\"599\" data-end=\"721\"\u003e\n\u003cstrong data-start=\"602\" data-end=\"620\"\u003eTest Operation\u003c\/strong\u003e – Verify that the trap properly discharges condensate and doesn’t allow excessive steam to escape.\u003c\/li\u003e\n\u003cli data-start=\"722\" data-end=\"851\"\u003e\n\u003cstrong data-start=\"725\" data-end=\"752\"\u003eExamine Seals \u0026amp; Gaskets\u003c\/strong\u003e – Replace any worn or damaged seals or gaskets to maintain pressure integrity and prevent leaks.\u003c\/li\u003e\n\u003cli data-start=\"852\" data-end=\"982\"\u003e\n\u003cstrong data-start=\"855\" data-end=\"887\"\u003eSchedule Regular Inspections\u003c\/strong\u003e – Frequent checks and maintenance help extend the lifespan and efficiency of the steam trap.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Armstrong Air","offers":[{"title":"Default Title","offer_id":46383714402529,"sku":"C5297-50","price":385.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/117261_1429635_primary_9.jpg?v=1746036948","url":"https:\/\/sportsteez.com\/products\/armstrong-international-c5297-50-880-series-1-2-in-450f-250-psi-steam-trap","provider":"EP","version":"1.0","type":"link"}