{"product_id":"armstrong-international-c5297-69-881-inverted-bucket-steam-trap-with-strainer-3-4-inch-npt-30-psi","title":"Armstrong International C5297-69 881 Inverted Bucket Steam Trap with Strainer 3\/4 Inch NP - C5297-69T 30 PSI","description":"\u003ch3\u003eArmstrong International C5297-69 881 Inverted Bucket Steam Trap with Strainer 3\/4 Inch NP - C5297-69T 30 PSI\u003c\/h3\u003e\n\u003cp\u003eThe Armstrong International Inverted Bucket Steam Trap, model 881, epitomizes efficiency and durability in steam system management. Built for horizontal in-line configuration, this device integrates a strainer and offers a 3\/4 inch NPT connection, suitable for both commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Armstrong International Inverted Bucket Steam Trap, model 881, epitomizes efficiency and durability in steam system management. Built for horizontal in-line configuration, this device integrates a strainer and offers a 3\/4 inch NPT connection, suitable for both commercial and industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMaximizes steam usage by allowing steam to enter from the bottom and condensate to discharge from the top.\u003c\/li\u003e\n\u003cli\u003eFeaturing a robust cast iron construction, ensuring long-term resistance to wear and corrosion.\u003c\/li\u003e\n\u003cli\u003eDesigned with a simple leverage system to handle pressures up to 30 psi and steam capacities up to 1000 pounds per hour.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eMPN\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eC5297-69\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eArmstrong International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eBody Material\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3\/4 inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e30 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOrifice Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3\/16 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eIn-Line Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e6.05 pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e880 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSteam Trap Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eInverted Bucket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"206\" data-end=\"282\"\u003e\n\u003cstrong data-start=\"208\" data-end=\"227\"\u003e30 PSI Capacity\u003c\/strong\u003e – Designed for low-to-medium pressure steam systems.\u003c\/li\u003e\n\u003cli data-start=\"283\" data-end=\"381\"\u003e\n\u003cstrong data-start=\"285\" data-end=\"311\"\u003eInverted Bucket Design\u003c\/strong\u003e – Ensures efficient condensate removal while minimizing steam loss.\u003c\/li\u003e\n\u003cli data-start=\"382\" data-end=\"473\"\u003e\n\u003cstrong data-start=\"384\" data-end=\"405\"\u003eBuilt-In Strainer\u003c\/strong\u003e – Prevents debris from entering the trap, extending its lifespan.\u003c\/li\u003e\n\u003cli data-start=\"474\" data-end=\"563\"\u003e\n\u003cstrong data-start=\"476\" data-end=\"499\"\u003e3\/4\" NPT Connection\u003c\/strong\u003e – Standard threading for easy installation and compatibility.\u003c\/li\u003e\n\u003cli data-start=\"564\" data-end=\"668\"\u003e\n\u003cstrong data-start=\"566\" data-end=\"590\"\u003eDurable Construction\u003c\/strong\u003e – Designed for reliability in industrial and commercial steam applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"414\" data-end=\"629\"\u003e\u003cstrong data-start=\"414\" data-end=\"465\"\u003eQ: How does an inverted bucket steam trap work?\u003c\/strong\u003e\u003cbr data-start=\"465\" data-end=\"468\"\u003eA: It uses an internal bucket mechanism that rises and falls with condensate levels, allowing water to drain while keeping steam trapped for energy efficiency.\u003c\/p\u003e\n\u003cp data-start=\"631\" data-end=\"835\"\u003e\u003cstrong data-start=\"631\" data-end=\"691\"\u003eQ: What applications is this steam trap best suited for?\u003c\/strong\u003e\u003cbr data-start=\"691\" data-end=\"694\"\u003eA: Ideal for industrial steam systems, process heating, and HVAC applications requiring reliable condensate removal and steam conservation.\u003c\/p\u003e\n\u003cp data-start=\"837\" data-end=\"1036\"\u003e\u003cstrong data-start=\"837\" data-end=\"883\"\u003eQ: Why is the built-in strainer important?\u003c\/strong\u003e\u003cbr data-start=\"883\" data-end=\"886\"\u003eA: The strainer helps prevent debris and contaminants from entering the steam trap, reducing the risk of clogging and extending the trap’s lifespan.\u003c\/p\u003e\n\u003cp data-start=\"1038\" data-end=\"1173\"\u003e\u003cstrong data-start=\"1038\" data-end=\"1081\"\u003eQ: Is this steam trap energy-efficient?\u003c\/strong\u003e\u003cbr data-start=\"1081\" data-end=\"1084\"\u003eA: Yes, it minimizes steam loss, improving system efficiency and reducing energy costs.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"78\" data-end=\"155\"\u003e\n\u003cstrong data-start=\"81\" data-end=\"100\"\u003eCheck for Leaks\u003c\/strong\u003e – Inspect pipe connections for steam or water leaks.\u003c\/li\u003e\n\u003cli data-start=\"156\" data-end=\"242\"\u003e\n\u003cstrong data-start=\"159\" data-end=\"180\"\u003eMonitor Operation\u003c\/strong\u003e – Listen for unusual noises indicating blockage or failure.\u003c\/li\u003e\n\u003cli data-start=\"243\" data-end=\"317\"\u003e\n\u003cstrong data-start=\"246\" data-end=\"268\"\u003eClean the Strainer\u003c\/strong\u003e – Remove debris regularly to prevent clogging.\u003c\/li\u003e\n\u003cli data-start=\"318\" data-end=\"393\"\u003e\n\u003cstrong data-start=\"321\" data-end=\"347\"\u003eInspect Bucket \u0026amp; Valve\u003c\/strong\u003e – Ensure smooth movement and a proper seal.\u003c\/li\u003e\n\u003cli data-start=\"394\" data-end=\"481\"\u003e\n\u003cstrong data-start=\"397\" data-end=\"423\"\u003eVerify Discharge Cycle\u003c\/strong\u003e – Confirm proper drainage without excessive steam loss.\u003c\/li\u003e\n\u003cli data-start=\"482\" data-end=\"555\"\u003e\n\u003cstrong data-start=\"485\" data-end=\"513\"\u003eMaintain Pressure Limits\u003c\/strong\u003e – Keep system within the 30 PSI rating.\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"642\"\u003e\n\u003cstrong data-start=\"559\" data-end=\"591\"\u003eSchedule Regular Maintenance\u003c\/strong\u003e – Routine checks extend efficiency and lifespan.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Armstrong Air","offers":[{"title":"Default Title","offer_id":46383724658913,"sku":"C5297-69","price":383.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/171216461.jpg?v=1746037561","url":"https:\/\/sportsteez.com\/products\/armstrong-international-c5297-69-881-inverted-bucket-steam-trap-with-strainer-3-4-inch-npt-30-psi","provider":"EP","version":"1.0","type":"link"}