{"product_id":"armstrong-international-c5318-32-armstrong-814-inverted-bucket-trap","title":"Armstrong International C5318-32 Armstrong 814 Inverted Bucket Trap - C5318-32","description":"\u003ch2\u003eArmstrong International C5318-32 Armstrong 814 Inverted Bucket Trap - C5318-32\u003c\/h2\u003e\n\u003cp\u003eThe Armstrong 814 Inverted Bucket Steam Trap, model C5318-32 from Armstrong International, facilitates precise steam management with its 1-inch NPT in-line horizontal configuration. This product is crafted from robust cast iron, ensuring durability and resistance against wear, corrosion, and hydraulic shock. It efficiently handles up to 6,000 pounds of steam per hour, apt for high-demand environments\u003c\/p\u003e\n\u003cp\u003e.The Armstrong 814 model excels in performance under varying loads and back pressures and features easy maintenance of venting air and non-condensable gases. It’s ideal for industrial applications requiring reliable and efficient steam trapping.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e180 PSI maximum operating pressure.\u003c\/li\u003e\n\u003cli\u003eDesigned for venting air quickly in heat exchange systems.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty stainless steel bucket included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e Specifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eMaterial\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e180 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOrifice Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e9\/32 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCapacity\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e6,000 lbs\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eIn-Line Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eArmstrong International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMPN\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eC5318-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Expect Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"169\" data-start=\"30\"\u003e\n\u003cstrong data-end=\"62\" data-start=\"32\"\u003eEfficient Steam Management\u003c\/strong\u003e: Inverted bucket design ensures reliable steam and condensate management for optimal system performance.\u003c\/li\u003e\n\u003cli data-end=\"287\" data-start=\"170\"\u003e\n\u003cstrong data-end=\"196\" data-start=\"172\"\u003eDurable Construction\u003c\/strong\u003e: Built with high-quality materials for long-lasting reliability in demanding conditions.\u003c\/li\u003e\n\u003cli data-end=\"408\" data-start=\"288\"\u003e\n\u003cstrong data-end=\"318\" data-start=\"290\"\u003eHigh-Pressure Capability\u003c\/strong\u003e: Suitable for various steam systems, providing effective operation even under pressure.\u003c\/li\u003e\n\u003cli data-end=\"524\" data-start=\"409\"\u003e\n\u003cstrong data-end=\"432\" data-start=\"411\"\u003ePrecise Operation\u003c\/strong\u003e: Ensures efficient air and condensate removal, maintaining the efficiency of your system.\u003c\/li\u003e\n\u003cli data-end=\"649\" data-start=\"525\"\u003e\n\u003cstrong data-end=\"548\" data-start=\"527\"\u003eEasy Installation\u003c\/strong\u003e: Designed for seamless integration into existing steam systems, simplifying setup and replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-end=\"365\" data-start=\"103\"\u003e\u003cstrong data-end=\"176\" data-start=\"103\"\u003eQ: What is the Armstrong International C5318-32 Inverted Bucket Trap?\u003c\/strong\u003e\u003cbr data-end=\"179\" data-start=\"176\"\u003eA: The C5318-32 is a high-efficiency inverted bucket steam trap designed for condensate removal in steam systems, offering reliable performance in industrial and commercial applications.\u003c\/p\u003e\n\u003cp data-end=\"802\" data-start=\"605\"\u003e\u003cstrong data-end=\"662\" data-start=\"605\"\u003eQ: Is this steam trap suitable for all steam systems?\u003c\/strong\u003e\u003cbr data-end=\"665\" data-start=\"662\"\u003eA: The C5318-32 is ideal for use in a variety of steam systems. Verify compatibility with your system’s specifications before purchasing.\u003c\/p\u003e\n\u003cp data-end=\"1037\" data-start=\"804\"\u003e\u003cstrong data-end=\"867\" data-start=\"804\"\u003eQ: How does the inverted bucket design improve performance?\u003c\/strong\u003e\u003cbr data-end=\"870\" data-start=\"867\"\u003eA: The inverted bucket design allows for efficient condensate drainage while preventing water hammer, ensuring optimal system operation and reducing maintenance needs.\u003c\/p\u003e\n\u003cp data-end=\"1197\" data-start=\"1039\"\u003e\u003cstrong data-end=\"1088\" data-start=\"1039\"\u003eQ: Does it require professional installation?\u003c\/strong\u003e\u003cbr data-end=\"1091\" data-start=\"1088\"\u003eA: Yes, professional installation is recommended for optimal setup and to ensure long-lasting performance.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"262\" data-start=\"116\"\u003e\n\u003cstrong data-end=\"140\" data-start=\"119\"\u003eInspect for Leaks\u003c\/strong\u003e – Regularly check for steam or fluid leaks around the trap's connections to ensure a secure seal and efficient operation.\u003c\/li\u003e\n\u003cli data-end=\"416\" data-start=\"263\"\u003e\n\u003cstrong data-end=\"299\" data-start=\"266\"\u003eClean the Bucket and Strainer\u003c\/strong\u003e – Periodically clean the inverted bucket and strainer to remove debris or scale buildup that may hinder performance.\u003c\/li\u003e\n\u003cli data-end=\"572\" data-start=\"417\"\u003e\n\u003cstrong data-end=\"443\" data-start=\"420\"\u003eCheck for Corrosion\u003c\/strong\u003e – Inspect the trap’s components for signs of rust or corrosion, particularly around the inlet and outlet, and replace if needed.\u003c\/li\u003e\n\u003cli data-end=\"716\" data-start=\"573\"\u003e\n\u003cstrong data-end=\"602\" data-start=\"576\"\u003eVerify Bucket Movement\u003c\/strong\u003e – Ensure the inverted bucket moves freely and isn’t obstructed by buildup or wear that could affect its function.\u003c\/li\u003e\n\u003cli data-end=\"857\" data-start=\"717\"\u003e\n\u003cstrong data-end=\"740\" data-start=\"720\"\u003eMonitor Pressure\u003c\/strong\u003e – Make sure the trap operates within its recommended pressure range to avoid over-pressurization and prevent damage.\u003c\/li\u003e\n\u003cli data-end=\"990\" data-start=\"858\"\u003e\n\u003cstrong data-end=\"890\" data-start=\"861\"\u003eCheck for Proper Drainage\u003c\/strong\u003e – Confirm that the condensate drainage is unobstructed and flows properly to prevent water buildup.\u003c\/li\u003e\n\u003cli data-end=\"1135\" data-start=\"991\"\u003e\n\u003cstrong data-end=\"1015\" data-start=\"994\"\u003eAnnual Inspection\u003c\/strong\u003e – Have a technician perform an annual inspection to ensure the trap functions as intended and address any issues early.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Armstrong Air","offers":[{"title":"Default Title","offer_id":46383712141537,"sku":"C5318-32","price":1103.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/171214117_1_8.jpg?v=1746036826","url":"https:\/\/sportsteez.com\/products\/armstrong-international-c5318-32-armstrong-814-inverted-bucket-trap","provider":"EP","version":"1.0","type":"link"}