{"product_id":"armstrong-international-d502310-armstrong-883-inverted-bucket-steam-trap-strainer-1-inch-npt-15-psi","title":"Armstrong International D502310 Armstrong 883 Inverted Bucket Steam Trap Strainer 1 Inch NPT 15 PSI - D502310","description":"\u003ch2\u003eArmstrong International D502310 Armstrong 883 Inverted Bucket Steam Trap Strainer 1 Inch NPT 15 PSI - D502310\u003c\/h2\u003e\n\u003cp\u003eThe Armstrong International model 883 inverted bucket steam trap is engineered for reliability and performance, ideally suited for heat exchange equipment where air and non-condensable gases need to be vented swiftly. Fitting a 1 inch NPT pipe connection in an inline horizontal setup, and capable of handling up to 15 psi maximum operating pressure. The model 883 is constructed from durable cast iron, featuring an integral strainer and a simple leverage system for effective steam trapping.\u003c\/p\u003e\n\u003cp\u003eThe Armstrong 883 provides significant durability and operational efficiency with its sturdy design and capacity to handle significant steam loads, suited for extensive industrial applications. It also includes a heavy-duty stainless steel bucket which enhances the trap’s longevity and performance.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e1 inch pipe connection in an inline horizontal configuration enhances fitting flexibility.\u003c\/li\u003e\n\u003cli\u003eConstructed from cast iron providing high resistance to wear, corrosion, and hydronic shock.\u003c\/li\u003e\n\u003cli\u003eEfficient handling of 3,900 pounds per hour steam capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e Specifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-0lax\"\u003eBrand\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eArmstrong International\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eMPN\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eD502310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1 inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eMax Pressure\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e15 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eCapacity\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3,900 lbs\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e883\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Expect Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"162\" data-start=\"30\"\u003e\n\u003cstrong data-end=\"68\" data-start=\"32\"\u003eHigh-Efficiency Steam Management\u003c\/strong\u003e: Inverted bucket design ensures effective condensate removal, improving system performance.\u003c\/li\u003e\n\u003cli data-end=\"286\" data-start=\"163\"\u003e\n\u003cstrong data-end=\"189\" data-start=\"165\"\u003eDurable Construction\u003c\/strong\u003e: Built with high-quality materials for long-lasting operation in demanding steam applications.\u003c\/li\u003e\n\u003cli data-end=\"388\" data-start=\"287\"\u003e\n\u003cstrong data-end=\"319\" data-start=\"289\"\u003eOptimized for Low Pressure\u003c\/strong\u003e: Rated for 15 PSI, making it ideal for low-pressure steam systems.\u003c\/li\u003e\n\u003cli data-end=\"495\" data-start=\"389\"\u003e\n\u003cstrong data-end=\"414\" data-start=\"391\"\u003eIntegrated Strainer\u003c\/strong\u003e: Helps prevent debris buildup, reducing maintenance and enhancing reliability.\u003c\/li\u003e\n\u003cli data-end=\"612\" data-start=\"496\"\u003e\n\u003cstrong data-end=\"519\" data-start=\"498\"\u003eEasy Installation\u003c\/strong\u003e: 1-inch NPT threading allows for quick and secure integration into existing steam systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-end=\"342\" data-start=\"114\"\u003e\u003cstrong data-end=\"182\" data-start=\"114\"\u003eQ: What is the Armstrong D502310 883 Inverted Bucket Steam Trap?\u003c\/strong\u003e\u003cbr data-end=\"185\" data-start=\"182\"\u003eA: The D502310 is a 1-inch NPT, 15 PSI inverted bucket steam trap with an integrated strainer, designed for efficient condensate drainage in steam systems.\u003c\/p\u003e\n\u003cp data-end=\"762\" data-start=\"576\"\u003e\u003cstrong data-end=\"631\" data-start=\"576\"\u003eQ: What systems is this steam trap compatible with?\u003c\/strong\u003e\u003cbr data-end=\"634\" data-start=\"631\"\u003eA: The Armstrong 883 is ideal for industrial and commercial steam applications. Check system specifications for compatibility.\u003c\/p\u003e\n\u003cp data-end=\"977\" data-start=\"764\"\u003e\u003cstrong data-end=\"823\" data-start=\"764\"\u003eQ: How does this steam trap improve system performance?\u003c\/strong\u003e\u003cbr data-end=\"826\" data-start=\"823\"\u003eA: It enhances energy efficiency by preventing steam loss, effectively removing condensate, and protecting equipment from water hammer and corrosion.\u003c\/p\u003e\n\u003cp data-end=\"1123\" data-start=\"979\"\u003e\u003cstrong data-end=\"1028\" data-start=\"979\"\u003eQ: Does it require professional installation?\u003c\/strong\u003e\u003cbr data-end=\"1031\" data-start=\"1028\"\u003eA: Yes, professional installation is recommended to ensure proper operation and longevity.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"231\" data-start=\"127\"\u003e\n\u003cstrong data-end=\"149\" data-start=\"130\"\u003eCheck for Leaks\u003c\/strong\u003e – Regularly inspect connections and seals to prevent steam or condensate leaks.\u003c\/li\u003e\n\u003cli data-end=\"351\" data-start=\"232\"\u003e\n\u003cstrong data-end=\"257\" data-start=\"235\"\u003eClean the Strainer\u003c\/strong\u003e – Periodically remove debris and buildup from the strainer to maintain efficient operation.\u003c\/li\u003e\n\u003cli data-end=\"472\" data-start=\"352\"\u003e\n\u003cstrong data-end=\"381\" data-start=\"355\"\u003eMonitor Trap Operation\u003c\/strong\u003e – Ensure the steam trap is discharging condensate properly and not stuck open or closed.\u003c\/li\u003e\n\u003cli data-end=\"581\" data-start=\"473\"\u003e\n\u003cstrong data-end=\"499\" data-start=\"476\"\u003eCheck for Blockages\u003c\/strong\u003e – Scale and dirt can clog the trap; flush it as needed to maintain proper flow.\u003c\/li\u003e\n\u003cli data-end=\"688\" data-start=\"582\"\u003e\n\u003cstrong data-end=\"610\" data-start=\"585\"\u003eInspect for Corrosion\u003c\/strong\u003e – Look for signs of rust or wear, especially in high-moisture environments.\u003c\/li\u003e\n\u003cli data-end=\"802\" data-start=\"689\"\u003e\n\u003cstrong data-end=\"718\" data-start=\"692\"\u003eVerify Proper Pressure\u003c\/strong\u003e – Ensure the system is operating within the trap’s 15 PSI rating to avoid damage.\u003c\/li\u003e\n\u003cli data-end=\"898\" data-start=\"803\"\u003e\n\u003cstrong data-end=\"825\" data-start=\"806\"\u003eTest Efficiency\u003c\/strong\u003e – Use a steam trap testing device or listen for proper cycling sounds.\u003c\/li\u003e\n\u003cli data-end=\"1023\" data-start=\"899\"\u003e\n\u003cstrong data-end=\"934\" data-start=\"902\"\u003eSchedule Routine Maintenance\u003c\/strong\u003e – Have a professional inspect and service the steam trap annually to prevent failures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Armstrong Air","offers":[{"title":"Default Title","offer_id":46383700803809,"sku":"D502310","price":841.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/171214153.jpg?v=1746036352","url":"https:\/\/sportsteez.com\/products\/armstrong-international-d502310-armstrong-883-inverted-bucket-steam-trap-strainer-1-inch-npt-15-psi","provider":"EP","version":"1.0","type":"link"}