{"product_id":"chicago-pneumatic-rcp-c10123vs-air-compressor-10hp-120-gal-two-stage-3-phase-208-230v-iron-series-new","title":"Chicago Pneumatic RCP-C10123VS Air Compressor 10HP 120 Gal. Two Stage 3-Phase 208-230V Iron Series New","description":"\u003cp\u003e\u003c!-- x-tinymce\/html --\u003eChicago Pneumatic's RCP Iron Series air compressors feature all cast iron pumps. Equipped with finned coolers and a splash lubricated oil system for unmatched heat dissipation. Featuring automotive style wrist pins and connecting rod bearings, concentric ring valves, and start-stop pressure switch control. All units are 100% tested at full pressure.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cdiv class=\"pdp__features__left\"\u003e\n\u003cul class=\"pdp__features__left__list\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll Cast Iron Pump Construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive Style Rod Bearings and Wrist Pins\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcentric Ring Valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSplash Lubricated Oil System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pdp__features__right\"\u003e\n\u003cul class=\"pdp__features__right__list\"\u003e\n\u003cli\u003e\n\u003cp\u003eStart-Stop Pressure Switch Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully Enclosed Belt Guard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-aukg{background-color:#FFF;color:#121212;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-8t0v{background-color:#FFF;color:#121212;text-align:left;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eItem Model #\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-8t0v\"\u003eRCP-C10123VS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eAC 208-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAmp Draw\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e26-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eRecommended Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e60 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eHorsepower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003ePump Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eTwo Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCFM @ 100 PSI\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax PSI\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003ePump Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003ePump Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eBelt Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eOil System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eSplash Lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMagnetic Starter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eTank Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e120 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eTank Orientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInlet\/Outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e42\" x 30\" x 74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-aukg\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-8t0v\"\u003e890 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003ePackage Contents\u003c\/h5\u003e\n\u003cp class=\"pdp__specs__row__right__package__text\"\u003eChicago Pneumatic RCP-C10123VS Air Compressor Iron Series\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful 10HP Motor\u003c\/strong\u003e – Delivers \u003cstrong\u003econsistent, high-efficiency performance\u003c\/strong\u003e, ideal for medium-to-heavy-duty industrial tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120 Gal. Tank\u003c\/strong\u003e – Large capacity offers \u003cstrong\u003eextended run times\u003c\/strong\u003e, reducing the need for frequent refills in demanding environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Compression\u003c\/strong\u003e – Provides \u003cstrong\u003esuperior efficiency\u003c\/strong\u003e and air delivery, ideal for applications requiring sustained, reliable pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Iron Series Construction\u003c\/strong\u003e – Built with \u003cstrong\u003erugged iron components\u003c\/strong\u003e to ensure long-lasting performance and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Phase Power\u003c\/strong\u003e – Operates on \u003cstrong\u003e208-230V three-phase power\u003c\/strong\u003e, providing stable and efficient operation for commercial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Maintenance \u0026amp; Quiet\u003c\/strong\u003e – Designed for \u003cstrong\u003eminimal upkeep\u003c\/strong\u003e and quieter operation, making it suitable for workplaces that prioritize noise reduction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the key features of the Chicago Pneumatic RCP-C10123VS air compressor?\u003c\/strong\u003e\u003cbr\u003eA: It features a 10HP motor, an 120-gallon tank, and operates on a 3-phase 208-230V power supply, designed for heavy-duty, industrial use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of compressor is it?\u003c\/strong\u003e\u003cbr\u003eA: The RCP-C10123VS is a two-stage air compressor, providing higher air pressure and efficiency, ideal for demanding applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the tank capacity?\u003c\/strong\u003e\u003cbr\u003eA: The compressor is equipped with a large 120-gallon tank, allowing for extended air supply during continuous operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this compressor suitable for industrial use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, with a 10HP motor and a two-stage system, it is designed for heavy-duty industrial environments requiring consistent performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this air compressor require professional installation?\u003c\/strong\u003e\u003cbr\u003eA: While installation can be straightforward, professional installation is recommended to ensure safety and optimal performance.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tip\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil Change\u003c\/strong\u003e – Replace the oil every 500 hours or according to the manufacturer's recommendations to maintain lubrication and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrain the Tank\u003c\/strong\u003e – Empty the tank's moisture daily using the drain valve to prevent rust and corrosion inside the tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean or Replace Air Filters\u003c\/strong\u003e – Inspect the air filters regularly, clean them as needed, and replace when they show signs of wear to maintain airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Belts \u0026amp; Pulleys\u003c\/strong\u003e – Check for wear, proper tension, and alignment to ensure power is efficiently transferred from the motor to the pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck for Leaks\u003c\/strong\u003e – Inspect all fittings and connections for air leaks and tighten any loose components to prevent energy loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Oil Level\u003c\/strong\u003e – Regularly check oil levels and top up as necessary to ensure the compressor runs smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor Pressure Settings\u003c\/strong\u003e – Ensure pressure settings are within the recommended range to optimize performance and prevent overloading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep the Compressor Clean\u003c\/strong\u003e – Clean the motor, pump, and cooling fins regularly to avoid dirt buildup, which can lead to overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnsure Proper Ventilation\u003c\/strong\u003e – Make sure the compressor is placed in a well-ventilated area to prevent overheating and maintain efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EP Hobbies \u0026 Co.","offers":[{"title":"Default Title","offer_id":46426131235041,"sku":"8090253066","price":4267.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/p59303_1-1729103115954_1_9.png?v=1746789221","url":"https:\/\/sportsteez.com\/products\/chicago-pneumatic-rcp-c10123vs-air-compressor-10hp-120-gal-two-stage-3-phase-208-230v-iron-series-new","provider":"EP","version":"1.0","type":"link"}