{"product_id":"ecotemp-wca4244gka-2-ton-15-seer-multi-speed-central-air-conditioner-split-system-multiposition-ha19766","title":"EcoTemp WCA4244GKA 2 Ton 15 SEER Multi Speed Central Air Conditioner Split System - Multiposition - HA19766","description":"\u003ch2\u003eStay Cool Our Efficient And Durable Air Conditioning Units. Trust EcoTemp To Keep You Comfortable And Save You Money On Your Energy Bill.\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEcoTemp WCA4 Air Conditioner\u003c\/strong\u003e is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes s\u003cstrong\u003ecroll compressors\u003c\/strong\u003e on all models and a\u003cstrong\u003e durable copper tube \/ aluminum fin coil,\u003c\/strong\u003e providing long-lasting and efficient performance.\u003c\/p\u003e\n\u003cp\u003eInstalling and servicing the WCA4 Air Conditioner is simple, thanks to its \u003cstrong\u003eeasy access service valves and external high and low refrigerant service ports.\u003c\/strong\u003e Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.\u003c\/p\u003e\n\u003cp\u003eThe WCA4 Air Conditioner is factory charged with\u003cstrong\u003e R-410A refrigerant\u003c\/strong\u003e, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a \u003cstrong\u003epre-painted cabinet finish over galvanized steel and a coated inlet grille with 3\/8” (10mm) grille spacing\u003c\/strong\u003e for extra protection against wear and tear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWCA4244GKA Air Conditioner Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAir Conditioner\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e14 Seer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR-410A Refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-5 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSplit System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e208\/230 Volt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-Phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWAHL244C Fan Coil Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFan Coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1.5-5 TON\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e600-1750 CFM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-39o3{background-color:#efefef;border-color:#000000;color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n.tg .tg-v0nz{background-color:#ffffff;border-color:#000000;color:#000000;text-align:center;vertical-align:top}\n.tg .tg-vwo1{background-color:#000000;border-color:#000000;color:#000000;text-align:center;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eWCA4244GKA,WAHL244C\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAHRI Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e9762684\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Avg Coverage Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1,000 - 1,200 Sq Ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Cooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e2 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Cooling Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e15 SEER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eEER\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e12.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-39o3\"\u003eWCA4244GKA Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eWCA4244GKA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAvg Coverage Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1,000 - 1,200 Sq Ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCompressor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSingle Stage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e2 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLine Set Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSweat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLiquid Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e20 amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Height (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Length (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e25.75\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Width (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e25.75\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eRefrigerant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eR-410a\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e14 SEER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSuction Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/4 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSystem Application Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eCentral Split Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e10 Year Parts, 1 Year Unit Replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight (lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e140.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-39o3\"\u003eWAHL244C Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eWAHL244C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAir Flow Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eDownflow, Horizontal, Upflow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eFloor Mounted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBlower Motor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eVariable Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e2 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eHeat Strip Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eUp to 15 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLine Set Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSweat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLiquid Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e15 amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Height (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e49.625\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Length (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e22.06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Width (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e17.63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSuction Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e5\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSystem Application Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eCentral Split Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e10 Year Parts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight (lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e122.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eAdditional Information\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWCA4244GKA Air Conditioner\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRefrigeration Circuit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eScroll compressors on all models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCopper tube \/ aluminum fin coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEasy to Install and Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEasy Access service valves on all models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal high and low refrigerant service ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnly two screws to access control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory charged with R−410A refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuilt to Last\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePre−painted cabinet finish over galvanized steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoated inlet grille with 3\/8” (10mm) grille spacing for extra protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWAHL244C Fan Coil\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1−1\/2 Thru 5 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable For Environmentally Sound R−410a Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory Installed Txv Metering Device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSweat Connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAluminum Tube, Aluminum Fin Evaporator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary And Secondary Drain Fittings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple Electrical Entry Locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime Delay Relay (TDR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Installed Heater Packages From 5 Kw − 30 Kw Available Separately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHud Approved For Manufactured Housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e208\/230−1−60 Supply Voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnits Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Inch Thick Insulation With R Value Of 4.2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFilter (Washable) Available As Accessory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEcm 5−speed Motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConvertible To Downflow With Available Accessory Kit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo Heat (Plug) Kit Factory Installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProduct Manual\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-installations.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e✓EcoTemp WCA4 Installation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-specifications.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e✓\u003cspan\u003eEcoTemp WCA4 Specification Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wahl-installation.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e✓\u003cspan\u003eWAHL Installation Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wahl-specifications.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e✓\u003cspan\u003eWAHL Specification Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wahl-warrantly.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e✓\u003cspan\u003eWAHL Warranty Sheet\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-warranty.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003e✓WCA4 Warranty Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Cooling\u003c\/strong\u003e: With a 15 SEER rating, the EcoTemp WCA4244GKA offers reliable and energy-efficient cooling, helping to lower electricity costs while maintaining a comfortable environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Ton Capacity\u003c\/strong\u003e: Ideal for medium to large homes, providing ample cooling power to effectively manage indoor temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Speed Functionality\u003c\/strong\u003e: Features multi-speed settings, allowing for customized airflow and enhanced comfort based on your cooling needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiposition Installation\u003c\/strong\u003e: Designed for flexible installation options, making it easy to fit into a variety of home configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e: Built with high-quality components for long-lasting performance, ensuring reliability and consistent cooling year after year.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the EcoTemp WCA4244GKA 2 Ton Central Air Conditioner used for?\u003c\/strong\u003e\u003cbr\u003eA: The EcoTemp WCA4244GKA is a 2-ton, 15 SEER multi-speed central air conditioner split system, designed to efficiently cool residential or light commercial spaces with consistent performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does SEER mean, and how does it benefit me?\u003c\/strong\u003e\u003cbr\u003eA: SEER stands for Seasonal Energy Efficiency Ratio, and the 15 SEER rating of this unit ensures energy-efficient cooling, reducing electricity costs while maintaining optimal comfort in your space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this air conditioner suitable for multiple installation positions?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the EcoTemp WCA4244GKA is a multiposition system, allowing for flexible installation options, including horizontal, vertical, and upflow applications, depending on your home’s needs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How powerful is the EcoTemp WCA4244GKA air conditioner?\u003c\/strong\u003e\u003cbr\u003eA: With a 2-ton capacity, this system is ideal for medium-sized rooms or homes, providing reliable and efficient cooling to maintain a comfortable indoor environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why should I choose the EcoTemp WCA4244GKA air conditioner?\u003c\/strong\u003e\u003cbr\u003eA: Its energy-efficient 15 SEER rating, versatile multiposition installation options, and reliable cooling power make it an excellent choice for homeowners seeking comfort, efficiency, and flexibility in a central air conditioning system.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClean or Replace Air Filters\u003c\/strong\u003e: Check the air filters monthly and clean or replace them every 1-3 months, depending on usage. Clogged filters reduce airflow and can lead to system inefficiency or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect Coils Regularly\u003c\/strong\u003e: Clean the evaporator and condenser coils annually to prevent dust, dirt, and debris from accumulating, which can reduce the system’s efficiency. Use a coil cleaner and a soft brush to gently remove buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck Refrigerant Levels\u003c\/strong\u003e: Low refrigerant levels can indicate leaks and result in poor cooling performance. Have a professional check and refill refrigerant if necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClear Debris Around the Outdoor Unit\u003c\/strong\u003e: Ensure the outdoor condenser unit is clear of debris like leaves, dirt, and vegetation. A clear space of at least 2 feet around the unit allows proper airflow and prevents overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect the Condensate Drain\u003c\/strong\u003e: Check the condensate drain regularly to ensure it’s clear of blockages. A clogged drain can cause water damage or lead to mold growth. Use a wet\/dry vacuum to clean it if needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck the Ductwork\u003c\/strong\u003e: Inspect your ducts for leaks, cracks, or disconnections. Leaky ducts can reduce the system’s efficiency. Seal any gaps and have the ductwork cleaned periodically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor the Thermostat\u003c\/strong\u003e: Ensure the thermostat is operating correctly and maintaining consistent temperatures. Consider upgrading to a programmable thermostat for better control and energy savings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck the Insulation\u003c\/strong\u003e: Inspect the insulation around the refrigerant lines and ducts to ensure it is intact and free from damage. Proper insulation helps maintain energy efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnsure Proper Airflow\u003c\/strong\u003e: Make sure that all vents and registers are open and unobstructed. Blocked vents can reduce airflow and strain the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnnual Professional Tune-Up\u003c\/strong\u003e: Schedule a professional inspection and tune-up annually before the cooling season begins. A certified technician can check refrigerant levels, clean coils, check electrical components, and ensure optimal system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EcoTemp","offers":[{"title":"Default Title","offer_id":46419583140065,"sku":"HA19766","price":2255.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/2-ton-15-seer-multi-speed-ecotemp-central-air-conditioner-split-system-multiposition-ha19766-01.3269_419e955f-e083-4a2d-94a0-38f19b8285f5.jpg?v=1746524887","url":"https:\/\/sportsteez.com\/products\/ecotemp-wca4244gka-2-ton-15-seer-multi-speed-central-air-conditioner-split-system-multiposition-ha19766","provider":"EP","version":"1.0","type":"link"}