{"product_id":"ecotemp-wca4364gka-3-ton-15-seer-variable-speed-ecotemp-central-air-conditioner-split-system-multiposition-ha19770","title":"EcoTemp WCA4364GKA 3 Ton 15 SEER Variable Speed EcoTemp Central Air Conditioner Split System - Multiposition - HA19770","description":"\u003ch2\u003eStay Cool Our Efficient And Durable Air Conditioning Units. Trust EcoTemp To Keep You Comfortable And Save You Money On Your Energy Bill.\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEcoTemp WCA4 Air Conditioner\u003c\/strong\u003e is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes s\u003cstrong\u003ecroll compressors\u003c\/strong\u003e on all models and a\u003cstrong\u003e durable copper tube \/ aluminum fin coil,\u003c\/strong\u003e providing long-lasting and efficient performance.\u003c\/p\u003e\n\u003cp\u003eInstalling and servicing the WCA4 Air Conditioner is simple, thanks to its \u003cstrong\u003eeasy access service valves and external high and low refrigerant service ports.\u003c\/strong\u003e Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.\u003c\/p\u003e\n\u003cp\u003eThe WCA4 Air Conditioner is factory charged with\u003cstrong\u003e R-410A refrigerant\u003c\/strong\u003e, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a \u003cstrong\u003epre-painted cabinet finish over galvanized steel and a coated inlet grille with 3\/8” (10mm) grille spacing\u003c\/strong\u003e for extra protection against wear and tear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWCA4364GKA \u003c\/span\u003eAir Conditioner Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAir Conditioner\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e14 Seer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR-410A Refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-5 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSplit System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e208\/230 Volt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-Phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWAXL364A \u003c\/span\u003eFan Coil Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFan Coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1.5-5 TON\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e600-2000 CFM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-39o3{background-color:#efefef;border-color:#000000;color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n.tg .tg-v0nz{background-color:#ffffff;border-color:#000000;color:#000000;text-align:center;vertical-align:top}\n.tg .tg-vwo1{background-color:#000000;border-color:#000000;color:#000000;text-align:center;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e\u003cspan\u003eWCA4364GKA\u003c\/span\u003e,\u003cspan\u003eWAXL364A\u003c\/span\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAHRI Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e9529658\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Avg Coverage Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1,500 - 1,800 Sq Ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Cooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Cooling Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e15 SEER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eEER\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\" colspan=\"2\"\u003e\n\u003cspan\u003eWCA4364GKA\u003c\/span\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003eWCA4364GKA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAvg Coverage Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1,500 - 1,800 Sq Ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCompressor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSingle Stage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLine Set Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSweat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLiquid Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e30 amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Height (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e24.4375\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Length (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e31.1875\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Width (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e31.1875\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eRefrigerant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eR-410a\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e14 SEER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSuction Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e7\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSystem Application Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eCentral Split Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e10 Year Parts, 1 Year Unit Replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight (lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e151.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\" colspan=\"2\"\u003e\n\u003cspan\u003eWAXL364A \u003c\/span\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003eWAXL364A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAir Flow Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eDownflow, Horizontal, Upflow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eFloor Mounted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBlower Motor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eVariable Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eHeat Strip Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eUp to 15 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLine Set Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSweat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLiquid Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e15 amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Height (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e49.625\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Length (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e22.0625\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Width (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e21.375\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSuction Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/4 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSystem Application Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eCentral Split Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e10 Year Parts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight (lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e157.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eAdditional Information\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWCA4364GKA \u003c\/span\u003eAir Conditioner\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRefrigeration Circuit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eScroll compressors on all models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCopper tube \/ aluminum fin coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEasy to Install and Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEasy Access service valves on all models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal high and low refrigerant service ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnly two screws to access control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory charged with R−410A refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuilt to Last\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePre−painted cabinet finish over galvanized steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoated inlet grille with 3\/8” (10mm) grille spacing for extra protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWAXL364A \u003c\/span\u003eFan Coil\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1−1\/2 Thru 5 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmentally Sound R−410a Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiposition Installation − Upflow Or Horizontal Left Standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal Right With Minor Modification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Convertible To Downflow With Available Accessory Kit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTxv Metering Device Factory Installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSweat Connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary And Secondary Drain Fittings With Brass Inserts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3 Amp Automotive Type Fuse In Wire Harness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple Electrical Entry Locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime Delay Relay (TDR) Programmed In Motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Installed Heater Packages From 5 Kw − 30 Kw Available Separately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHud Approved For Manufactured Housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e208\/230−1−60 Supply Voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnits Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Inch (25mm) Thick Insulation With R Value Of 4.2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEcm Motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo Heat (Plug) Kit Factory Installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFilter (Washable) Factory Supplied\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProduct Manual\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-installations.pdf\" target=\"_blank\"\u003e✓EcoTemp WCA4 Installation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-specifications.pdf\" target=\"_blank\"\u003e✓\u003cspan\u003eEcoTemp WCA4 Specification Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-warranty.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e✓WCA4 Warranty Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/waxl-installation.pdf\" target=\"_blank\"\u003e✓WAXL Installation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-warranty.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/waxl-specifications.pdf\" target=\"_blank\"\u003e✓WAXL Specification Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-warranty.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/waxl-warranty.pdf\" target=\"_blank\"\u003e✓\u003cspan\u003eWAXL Warranty Sheet\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-warranty.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy-Efficient Cooling\u003c\/strong\u003e: With a 15 SEER rating, the EcoTemp WCA4364GKA ensures efficient cooling that reduces energy consumption while maintaining consistent comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Speed Technology\u003c\/strong\u003e: The variable speed motor optimizes airflow based on cooling demand, ensuring smoother, quieter, and more efficient temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Ton Capacity\u003c\/strong\u003e: Ideal for larger homes or spaces requiring high-capacity cooling, providing ample performance across multiple rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiposition Installation\u003c\/strong\u003e: Offers flexible installation options, making it adaptable to various home layouts for easier and more versatile setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability and Longevity\u003c\/strong\u003e: Designed with quality components for long-term performance, ensuring reliable, efficient cooling for years to come.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the EcoTemp WCA4364GKA 3 Ton Central Air Conditioner used for?\u003c\/strong\u003e\u003cbr\u003eA: The EcoTemp WCA4364GKA is a 3-ton, 15 SEER variable-speed central air conditioner split system, designed to provide efficient and consistent cooling for larger residential or light commercial spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is SEER, and how does the 15 SEER rating benefit me?\u003c\/strong\u003e\u003cbr\u003eA: SEER stands for Seasonal Energy Efficiency Ratio. The 15 SEER rating ensures energy-efficient cooling, helping to reduce electricity bills while maintaining consistent comfort throughout the year.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the variable-speed technology improve the system’s performance?\u003c\/strong\u003e\u003cbr\u003eA: The variable-speed blower motor allows the system to adjust airflow based on cooling demands, leading to quieter operation, better humidity control, and improved energy efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the EcoTemp WCA4364GKA be installed in various positions?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this air conditioner is a multiposition system, allowing for flexible installation in horizontal, vertical, or upflow configurations to accommodate different space requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why should I choose the EcoTemp WCA4364GKA air conditioner?\u003c\/strong\u003e\u003cbr\u003eA: The 15 SEER energy efficiency, variable-speed technology for enhanced comfort, and multiposition installation flexibility make the EcoTemp WCA4364GKA an excellent choice for cooling larger spaces efficiently and quietly.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReplace or Clean Air Filters\u003c\/strong\u003e: Inspect air filters monthly, and replace or clean them every 1-3 months. Clogged filters impede airflow, reducing efficiency and increasing the workload on your system. Regular filter maintenance ensures optimal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClean the Coils\u003c\/strong\u003e: Clean the evaporator and condenser coils annually to prevent dirt and debris buildup, which can affect heat exchange and reduce the system’s cooling efficiency. Use a coil cleaner and a soft brush to remove debris gently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck Refrigerant Levels\u003c\/strong\u003e: Low refrigerant levels can cause poor cooling performance and lead to system failure. Schedule an annual checkup with a professional technician to ensure the refrigerant is at the appropriate level and to repair any leaks if necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClear Debris Around the Outdoor Unit\u003c\/strong\u003e: Keep the outdoor condenser unit clear of debris like leaves, dirt, and branches. Maintain at least a 2-foot clearance around the unit to ensure proper airflow and prevent the unit from overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect the Condensate Drain\u003c\/strong\u003e: Regularly check the condensate drain for blockages, as clogs can lead to water damage or mold growth. If necessary, clean the drain with a wet\/dry vacuum to prevent backups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck Ductwork for Leaks\u003c\/strong\u003e: Inspect the ducts for any visible leaks, gaps, or disconnections. Leaky ducts waste energy and reduce cooling efficiency. Seal any gaps and schedule periodic duct cleaning to maintain proper airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTest and Calibrate the Thermostat\u003c\/strong\u003e: Ensure the thermostat is correctly calibrated and maintains the desired temperature. Consider upgrading to a smart thermostat for better control over your cooling settings and improved energy efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect Insulation\u003c\/strong\u003e: Check the insulation around the refrigerant lines and ducts for any damage or wear. Insulation prevents energy loss and ensures the system operates at peak efficiency, so repair or replace any damaged insulation as needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnsure Proper Airflow\u003c\/strong\u003e: Ensure that all vents and registers are open and unobstructed by furniture or curtains. Blocked airflow can reduce the system’s cooling ability and cause it to work harder, lowering efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSchedule Professional Maintenance\u003c\/strong\u003e: Arrange for annual professional maintenance, ideally before the cooling season. A certified HVAC technician will clean the coils, inspect the refrigerant, check electrical components, and verify that the variable-speed system is operating at optimal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EcoTemp","offers":[{"title":"Default Title","offer_id":46419583631585,"sku":"HA19770","price":2951.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/2-ton-15-seer-multi-speed-ecotemp-central-air-conditioner-split-system-multiposition-ha19766-01.3269_f2e8a8de-0dbd-49f4-a74d-d419dc8716cc.jpg?v=1746524919","url":"https:\/\/sportsteez.com\/products\/ecotemp-wca4364gka-3-ton-15-seer-variable-speed-ecotemp-central-air-conditioner-split-system-multiposition-ha19770","provider":"EP","version":"1.0","type":"link"}