{"product_id":"ecotemp-wca4424gka-3-5-ton-14-seer-multi-speed-central-air-conditioner-split-system-multiposition-ha19772","title":"EcoTemp WCA4424GKA 3.5 Ton 14 SEER Multi Speed Central Air Conditioner Split System - Multiposition - HA19772","description":"\u003ch2\u003eStay Cool Our Efficient And Durable Air Conditioning Units. Trust EcoTemp To Keep You Comfortable And Save You Money On Your Energy Bill.\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEcoTemp WCA4 Air Conditioner\u003c\/strong\u003e is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes s\u003cstrong\u003ecroll compressors\u003c\/strong\u003e on all models and a\u003cstrong\u003e durable copper tube \/ aluminum fin coil,\u003c\/strong\u003e providing long-lasting and efficient performance.\u003c\/p\u003e\n\u003cp\u003eInstalling and servicing the WCA4 Air Conditioner is simple, thanks to its \u003cstrong\u003eeasy access service valves and external high and low refrigerant service ports.\u003c\/strong\u003e Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.\u003c\/p\u003e\n\u003cp\u003eThe WCA4 Air Conditioner is factory charged with\u003cstrong\u003e R-410A refrigerant\u003c\/strong\u003e, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a \u003cstrong\u003epre-painted cabinet finish over galvanized steel and a coated inlet grille with 3\/8” (10mm) grille spacing\u003c\/strong\u003e for extra protection against wear and tear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWCA4424GKA \u003c\/span\u003eAir Conditioner Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAir Conditioner\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e14 Seer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR-410A Refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-5 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSplit System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e208\/230 Volt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1-Phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWAHL424B \u003c\/span\u003eFan Coil Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFan Coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1.5-5 TON\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e600-1750 CFM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-39o3{background-color:#efefef;border-color:#000000;color:#000000;font-weight:bold;text-align:center;vertical-align:top}\n.tg .tg-v0nz{background-color:#ffffff;border-color:#000000;color:#000000;text-align:center;vertical-align:top}\n.tg .tg-vwo1{background-color:#000000;border-color:#000000;color:#000000;text-align:center;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e\u003cspan\u003eWCA4424GKA\u003c\/span\u003e,\u003cspan\u003eWAHL424B\u003c\/span\u003e\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAHRI Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e9507436\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Avg Coverage Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e\u003cspan\u003e1,750 \u003c\/span\u003e- 2,1\u003cspan\u003e00 \u003c\/span\u003eSq Ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Cooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3.5 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBundle Cooling Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e14 SEER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eEER\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e11.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-39o3\"\u003e\n\u003cspan\u003eWCA4424GKA \u003c\/span\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003eWCA4424GKA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAvg Coverage Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1,750 - 2,100 Sq Ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCompressor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSingle Stage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3.5 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLine Set Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSweat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLiquid Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e35 amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Height (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e39.125\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Length (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e31.1875\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Width (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e31.1875\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eRefrigerant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eR-410a\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e14 SEER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSuction Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e7\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSystem Application Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eCentral Split Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e10 Year Parts, 1 Year Unit Replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight (lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003e232.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-vwo1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-39o3\"\u003e\n\u003cspan\u003eWAHL424B\u003c\/span\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan\u003eWAHL424B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAir Flow Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eDownflow, Horizontal, Upflow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eFloor Mounted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eBlower Motor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eVariable Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCooling Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3.5 Ton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e1-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eHeat Strip Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eUp to 20 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLine Set Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eSweat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eLiquid Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e3\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eMax Overcurrent Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e15 amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Height (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e49.625\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Length (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e22.06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eProduct Width (in)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e21.63\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSuction Line Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e7\/8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSystem Application Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eCentral Split Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e10 Year Parts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-39o3\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight (lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-v0nz\"\u003e\u003cspan style=\"font-weight: normal;\"\u003e157.0000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eAdditional Information\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWCA4424GKA \u003c\/span\u003eAir Conditioner\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRefrigeration Circuit\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eScroll compressors on all models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCopper tube \/ aluminum fin coil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEasy to Install and Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEasy Access service valves on all models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal high and low refrigerant service ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnly two screws to access control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory charged with R−410A refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuilt to Last\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePre−painted cabinet finish over galvanized steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoated inlet grille with 3\/8” (10mm) grille spacing for extra protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWAHL424B \u003c\/span\u003eFan Coil\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1−1\/2 Thru 5 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable For Environmentally Sound R−410a Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory Installed Txv Metering Device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSweat Connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAluminum Tube, Aluminum Fin Evaporator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary And Secondary Drain Fittings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple Electrical Entry Locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime Delay Relay (TDR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Installed Heater Packages From 5 Kw − 30 Kw Available Separately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHud Approved For Manufactured Housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e208\/230−1−60 Supply Voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnits Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Inch Thick Insulation With R Value Of 4.2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFilter (Washable) Available As Accessory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEcm 5−speed Motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConvertible To Downflow With Available Accessory Kit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo Heat (Plug) Kit Factory Installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProduct Manual\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-installations.pdf\" target=\"_blank\"\u003e✓EcoTemp WCA4 Installation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-specifications.pdf\" target=\"_blank\"\u003e✓\u003cspan\u003eEcoTemp WCA4 Specification Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wca4-warranty.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan\u003e✓WCA4 Warranty Sheet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wahl-installation.pdf\" target=\"_blank\"\u003e✓\u003cspan\u003eWAHL Installation Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wahl-specifications.pdf\" target=\"_blank\"\u003e✓\u003cspan\u003eWAHL Specification Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/daikin\/dcc-7to12t-installation.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.iwae.com\/media\/manuals\/ecotemp\/wahl-warrantly.pdf\" target=\"_blank\"\u003e✓\u003cspan\u003eWAHL Warranty Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Cooling Efficiency\u003c\/strong\u003e: With a 14 SEER rating, the EcoTemp WCA4424GKA offers solid cooling performance while keeping energy costs low, making it an economical choice for your home.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.5-Ton Capacity\u003c\/strong\u003e: Perfect for larger homes or spaces, providing ample cooling power to efficiently manage temperature across multiple rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Speed Operation\u003c\/strong\u003e: The multi-speed functionality allows for customizable airflow, adapting to your cooling needs for better comfort and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation\u003c\/strong\u003e: The multiposition design ensures easy and versatile installation, accommodating various home layouts for a seamless setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e: Built with high-quality materials, this system is designed for long-term reliability and consistent performance, even under heavy use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the EcoTemp WCA4424GKA 3.5 Ton Central Air Conditioner used for?\u003c\/strong\u003e\u003cbr\u003eA: The EcoTemp WCA4424GKA is a 3.5-ton, 14 SEER multi-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is SEER, and what benefits does the 14 SEER rating offer?\u003c\/strong\u003e\u003cbr\u003eA: SEER stands for Seasonal Energy Efficiency Ratio. The 14 SEER rating ensures that the system delivers reliable and cost-effective cooling while helping to reduce energy consumption compared to lower-rated units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What advantages does the multi-speed functionality provide?\u003c\/strong\u003e\u003cbr\u003eA: The multi-speed blower motor adjusts airflow based on cooling demands, ensuring quieter operation, better comfort, and increased energy efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the EcoTemp WCA4424GKA be installed in different positions?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this system is multiposition, offering flexibility to install it in horizontal, vertical, or upflow configurations, depending on your space and layout needs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why should I choose the EcoTemp WCA4424GKA air conditioner?\u003c\/strong\u003e\u003cbr\u003eA: With its 14 SEER energy efficiency, multi-speed functionality for improved comfort, and versatile multiposition installation, the EcoTemp WCA4424GKA is an ideal solution for efficiently cooling larger spaces.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReplace or Clean Air Filters\u003c\/strong\u003e: Check air filters every month and clean or replace them every 1-3 months. Clogged filters impede airflow, reduce system efficiency, and can cause strain on the system, leading to overheating or premature failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClean Evaporator and Condenser Coils\u003c\/strong\u003e: Clean both the evaporator and condenser coils at least once a year. Dirt and debris accumulation on the coils can cause poor heat transfer and affect the system's efficiency. Use a coil cleaner and a soft brush to remove buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck Refrigerant Levels\u003c\/strong\u003e: Have a licensed technician check the refrigerant levels annually. Low refrigerant levels can reduce cooling performance and damage the compressor. Ensure the system is properly charged with refrigerant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClear Outdoor Unit of Debris\u003c\/strong\u003e: Maintain at least a 2-foot clearance around the outdoor unit to allow proper airflow. Remove leaves, dirt, and other debris that could block airflow, prevent heat dissipation, and cause overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect the Condensate Drain\u003c\/strong\u003e: Regularly inspect the condensate drain for blockages. A clogged drain can lead to water damage, mold growth, or poor system performance. Clear the drain line using a wet\/dry vacuum or pipe cleaner if needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect Ductwork for Leaks\u003c\/strong\u003e: Leaky or disconnected ducts can reduce cooling efficiency and increase energy consumption. Inspect ductwork for leaks, gaps, or damage, and seal any visible issues. Consider having ducts cleaned periodically to optimize airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTest and Calibrate the Thermostat\u003c\/strong\u003e: Ensure the thermostat is functioning correctly and maintains a consistent temperature. If your system uses a programmable thermostat, adjust it for better control and energy savings. A smart thermostat can provide more flexibility and efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck Insulation\u003c\/strong\u003e: Inspect the insulation around refrigerant lines and ducts. Damaged insulation can lead to energy loss, causing the system to work harder. Replace any worn or damaged insulation to maintain optimal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnsure Proper Airflow\u003c\/strong\u003e: Ensure that all supply and return vents are open and unobstructed by furniture or curtains. Blocked airflow can reduce system efficiency, leading to higher energy consumption and strain on the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSchedule Annual Professional Maintenance\u003c\/strong\u003e: Arrange for an annual professional inspection to ensure your EcoTemp system is operating efficiently. A technician can clean the coils, check refrigerant levels, inspect the blower, and ensure the multi-speed system is functioning optimally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EcoTemp","offers":[{"title":"Default Title","offer_id":46419583664353,"sku":"HA19772","price":2923.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/2-ton-15-seer-multi-speed-ecotemp-central-air-conditioner-split-system-multiposition-ha19766-01.3269_dc0ede93-627e-4abf-af67-e1ce471b00cf.jpg?v=1746524924","url":"https:\/\/sportsteez.com\/products\/ecotemp-wca4424gka-3-5-ton-14-seer-multi-speed-central-air-conditioner-split-system-multiposition-ha19772","provider":"EP","version":"1.0","type":"link"}