{"product_id":"ic670alg240-ge-fanuc-field-control","title":"Fanuc Corporation  GE FANUC Field Control - IC670ALG240","description":"\u003ch2\u003eFanuc Corporation  GE FANUC Field Control - IC670ALG240\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\" data-sheets-value='{\"1\":2,\"2\":\"The IC670ALG240 is an 16-Point Analog Current source input module from the Field control series of GE Fanuc. This module has Sixteen (16) single-ended input channels configurable for 0-20 mA \/ 4-20 mA with digital resolution of 16 bits. This module supports ANSI Type 2 2-wire and 3-Wire transmitter wiring.\"}' data-sheets-userformat='{\"2\":705,\"3\":{\"1\":0},\"9\":1,\"10\":1,\"12\":0}'\u003eThe IC670ALG240 is an 16-Point Analog Current source input module from the Field control series of GE Fanuc. This module has Sixteen (16) single-ended input channels configurable for 0-20 mA \/ 4-20 mA with digital resolution of 16 bits. This module supports ANSI Type 2 2-wire and 3-Wire transmitter wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About IC670ALG240\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe IC670ALG240 is an analog input module from GE Fanuc. This module is specifically part of the Field I\/O control series that is designed for installation along a Bus Interface Unit (BIU) and an expansion rack. This module provides Sixteen (16) analog input channels in a single group, accepting current input signals in the form of 0-20 mA and 420 mA and may be operated at an input signal range of 0-25 mA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe IC670ALG240 can be used to interface field transmitters such as Pressure, Level, Flow, Temperature, Turbidity and similar types. It may also be used to interface output signals of panel meters, data loggers, single-loop controllers, Variable Frequency Drives (VFD), signal splitters, signal isolators and other devices. This module comes with a built-in Analog to Digital Converter (ADC) available to each input channels that converts the analog data to digital format with resolution of 16-bits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe IC670ALG240 has a maximum current draw of 251 mA from the BIU power supply. It has an operating temperature range of 0-55 Degree Celsius and requires a current loop power supply 20-28 VDC, nominal with 10% ripple voltage. It has temperature coefficient of +\/-.002% of value per degree C, typical, and +\/-.005% of value per degree C, maximum. This module supports ANSI Type 2 2-wire transmitter and Type 3 3-Wire transmitter wiring configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe IC670ALG240 is capable of performing internal diagnostics such as module not calibrated, calibration data out of range, calibration write failure, ready to calibrate, invalid command, A\/D conversion incomplete, Factory calibration not available, individual channel high and low alarm, underrange and overrange conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe GE IC670ALG240 input module is a 16-channel analog current input module. At a single time, the module is able to take in 16 loop inputs by using a common power supply. The module is able to accept 2-wire or 3-wire current transmissions and then change them into digital input values. The input current to the module ranges between 0 and 25 milliamps. The module supports both the word and bit data types. The IC670ALG240 input module can be easily calibrated and the calibration data can be stored in the flash memory. The module uses 50 Hertz and 60 Hertz frequencies for data acquisition. The module is intelligent and it comes with diagnostics and alarm features that can report over range and open wire alarms. The alarms in the module can be configured by the operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe GE Fanuc IC670ALG240 input module has a resolution of 16 bits. The input current span for 16 bits ranges between 0 and 25 milliamps. The current loop power supply of the module is between 20 and 28 Volts, and it has a maximum ripple of 10%. For operation, the temperature should be set between 0 and 55 degrees Celsius. The IC670ALG240 input module uses an active RC filter 2nd order as the hardware filter. The common mode rejection from the channel to the ground is 86 dB. The input module has several useful features. It comes with the Channel Active mode that helps to set a specific channel as active or inactive. It has advanced filtering options like the input filter, line filter, and averaging filter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer information\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eGE FANUC\u003c\/strong\u003e, now part of Emerson Automation Solutions, was a leading provider of industrial automation and control systems. Known for innovative solutions, GE FANUC played a key role in advancing manufacturing, offering a range of products including PLCs, CNCs, and HMI solutions.\u003c\/p\u003e\n\u003ch5\u003eSpecifications \u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003ePart Number\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eIC670ALG240\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eProduct Description\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eAnalog Current \/ Voltage Source Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eChannels\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8 (Single-ended configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Signal (Nominal)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0.0–20.48 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMaximum Current Input\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Current\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eADC Conversion Resolution\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e86 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eRipple\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e10% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eHardware Filter\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eRC 2nd order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eLoop Wiring\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eANSI Type 2 \u0026amp; Type 3 2-Wire Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Grouping\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eSingle group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eWiring Configuration\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eSingle-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e20–28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNominal Supply Voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCurrent Draw from BIU Supply\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e251 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eGround to Logic Isolation\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1500 VAC for 1 min; 250 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli class=\"\" data-end=\"252\" data-start=\"132\"\u003e\n\u003cp class=\"\" data-end=\"252\" data-start=\"134\"\u003e\u003cstrong data-end=\"164\" data-start=\"134\"\u003ePrecise Signal Processing:\u003c\/strong\u003e Handles 16 channels of analog current input, ideal for industrial sensor integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"348\" data-start=\"253\"\u003e\n\u003cp class=\"\" data-end=\"348\" data-start=\"255\"\u003e\u003cstrong data-end=\"280\" data-start=\"255\"\u003eEnhanced Calibration:\u003c\/strong\u003e Features field-recalibration for accurate and reliable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"461\" data-start=\"349\"\u003e\n\u003cp class=\"\" data-end=\"461\" data-start=\"351\"\u003e\u003cstrong data-end=\"377\" data-start=\"351\"\u003eRobust Alarm Features:\u003c\/strong\u003e Monitors high\/low, under\/overrange, and open wire conditions for improved safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"568\" data-start=\"462\"\u003e\n\u003cp class=\"\" data-end=\"568\" data-start=\"464\"\u003e\u003cstrong data-end=\"486\" data-start=\"464\"\u003eDigital Filtering:\u003c\/strong\u003e Includes 10 ms or 20 ms digital filtering to reduce noise and improve accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"673\" data-start=\"569\"\u003e\n\u003cp class=\"\" data-end=\"673\" data-start=\"571\"\u003e\u003cstrong data-end=\"596\" data-start=\"571\"\u003eSeamless Integration:\u003c\/strong\u003e Easily integrates into GE FANUC systems, offering scalable configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"764\" data-start=\"674\"\u003e\n\u003cp class=\"\" data-end=\"764\" data-start=\"676\"\u003e\u003cstrong data-end=\"697\" data-start=\"676\"\u003eGE FANUC Quality:\u003c\/strong\u003e Designed for reliability and precision in industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"\" data-end=\"354\" data-start=\"128\"\u003e\u003cstrong data-end=\"173\" data-start=\"128\"\u003eQ: What is the IC670ALG240 Field Control?\u003c\/strong\u003e\u003cbr data-end=\"176\" data-start=\"173\"\u003eA: It’s a GE Fanuc field control module designed for industrial automation systems, providing analog input functionality for seamless data acquisition from various field devices.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"564\" data-start=\"356\"\u003e\u003cstrong data-end=\"398\" data-start=\"356\"\u003eQ: What systems is it compatible with?\u003c\/strong\u003e\u003cbr data-end=\"401\" data-start=\"398\"\u003eA: This module is compatible with GE Fanuc field control systems and is often used in process control, manufacturing automation, and other industrial applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"797\" data-start=\"566\"\u003e\u003cstrong data-end=\"611\" data-start=\"566\"\u003eQ: What does the field control module do?\u003c\/strong\u003e\u003cbr data-end=\"614\" data-start=\"611\"\u003eA: It converts analog signals from field devices (e.g., sensors, transmitters) into digital data that can be processed by the control system, enabling accurate monitoring and control.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"992\" data-start=\"799\"\u003e\u003cstrong data-end=\"833\" data-start=\"799\"\u003eQ: Why choose the IC670ALG240?\u003c\/strong\u003e\u003cbr data-end=\"836\" data-start=\"833\"\u003eA: It ensures high precision in analog signal processing, contributing to reliable system performance and operational efficiency in industrial environments.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1159\" data-start=\"994\"\u003e\u003cstrong data-end=\"1024\" data-start=\"994\"\u003eQ: Is this an OEM product?\u003c\/strong\u003e\u003cbr data-end=\"1027\" data-start=\"1024\"\u003eA: Yes, it’s a genuine GE Fanuc part, ensuring compatibility, durability, and superior performance in industrial automation systems.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"65\" data-end=\"267\" class=\"\"\u003e\n\u003cp data-start=\"68\" data-end=\"267\" class=\"\"\u003e\u003cstrong data-start=\"68\" data-end=\"89\"\u003eVisual Inspection\u003c\/strong\u003e: Regularly inspect the module for visible signs of damage, such as burnt components, broken traces, or loose connectors. Pay close attention to the input and output terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"268\" data-end=\"466\" class=\"\"\u003e\n\u003cp data-start=\"271\" data-end=\"466\" class=\"\"\u003e\u003cstrong data-start=\"271\" data-end=\"291\"\u003eClean the Module\u003c\/strong\u003e: Use dry compressed air or an anti-static brush to remove dust, dirt, or debris. Avoid using liquid cleaners that could damage sensitive components or cause short circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"467\" data-end=\"694\" class=\"\"\u003e\n\u003cp data-start=\"470\" data-end=\"694\" class=\"\"\u003e\u003cstrong data-start=\"470\" data-end=\"505\"\u003eVerify Input and Output Signals\u003c\/strong\u003e: Ensure that the input and output signals fall within the recommended voltage ranges. Incorrect voltage levels can cause erroneous readings or malfunctioning of the field control module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"695\" data-end=\"902\" class=\"\"\u003e\n\u003cp data-start=\"698\" data-end=\"902\" class=\"\"\u003e\u003cstrong data-start=\"698\" data-end=\"731\"\u003eInspect Connectors and Wiring\u003c\/strong\u003e: Check connectors for proper attachment, cleanliness, and signs of wear or corrosion. Loose or corroded connections can cause intermittent signal failures or data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"903\" data-end=\"1076\" class=\"\"\u003e\n\u003cp data-start=\"906\" data-end=\"1076\" class=\"\"\u003e\u003cstrong data-start=\"906\" data-end=\"929\"\u003eCheck Solder Joints\u003c\/strong\u003e: Inspect solder joints for cracks, corrosion, or poor connections. Cold solder joints can lead to unreliable performance or intermittent issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1077\" data-end=\"1273\" class=\"\"\u003e\n\u003cp data-start=\"1080\" data-end=\"1273\" class=\"\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1099\"\u003eRun Diagnostics\u003c\/strong\u003e: Use diagnostic tools or software to test the module’s functionality. Look for any error codes or abnormal behavior that could indicate an issue with the module or wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1274\" data-end=\"1463\" class=\"\"\u003e\n\u003cp data-start=\"1277\" data-end=\"1463\" class=\"\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1301\"\u003eMonitor Power Supply\u003c\/strong\u003e: Ensure the module is receiving the correct input power supply. Voltage fluctuations or incorrect power levels can lead to instability or damage to the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1464\" data-end=\"1641\" class=\"\"\u003e\n\u003cp data-start=\"1467\" data-end=\"1641\" class=\"\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1493\"\u003eTemperature Monitoring\u003c\/strong\u003e: Confirm that the module operates within the specified temperature range. Overheating can damage the components and reduce the module’s lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1642\" data-end=\"1804\" class=\"\"\u003e\n\u003cp data-start=\"1645\" data-end=\"1804\" class=\"\"\u003e\u003cstrong data-start=\"1645\" data-end=\"1664\"\u003eCheck Grounding\u003c\/strong\u003e: Ensure that the module is properly grounded to prevent electrical noise or interference, which could impact signal quality and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1991\" class=\"\"\u003e\n\u003cp data-start=\"1809\" data-end=\"1991\" class=\"\"\u003e\u003cstrong data-start=\"1809\" data-end=\"1827\"\u003eESD Protection\u003c\/strong\u003e: Handle the module with proper electrostatic discharge (ESD) precautions, such as wrist straps and anti-static mats, to protect sensitive components from damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fanuc Corporation","offers":[{"title":"Default Title","offer_id":46426313326817,"sku":"IC670ALG240","price":2059.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/IC670ALG240_219b3777-93cd-4043-908e-7114e2da9fbb.webp?v=1748264740","url":"https:\/\/sportsteez.com\/products\/ic670alg240-ge-fanuc-field-control","provider":"EP","version":"1.0","type":"link"}