{"product_id":"pioneer-18-000-btu-20-seer-floor-ceiling-mini-split-air-conditioner-heat-pump-system-with-16-ft-line-sets-uyb018gmfilcad-16","title":"Pioneer 18,000 BTU 20 SEER Floor\/Ceiling Mini-Split Air Conditioner Heat Pump System with 16 ft. Line Sets - UYB018GMFILCAD-16","description":"\u003ch2\u003eioneer 18,000 BTU 20 SEER Floor\/Ceiling Mini-Split Air Conditioner Heat Pump System with 16 ft. Line Sets - UYB018GMFILCAD-16\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePioneer Mini Split offers a wide selection of flexible floor-ceiling mount ductless mini splits that are ideal for homes and commercial properties. These Flex Mount systems come with ductless indoor units that can be mounted in various positions based on requirements, including ductless air conditioning ceiling mounts. You can mount our indoor floor-ceiling flex mount mini split units of smaller-capacity systems as floor consoles or in low wall-attached positions. Our larger-capacity versions come with larger indoor units; you can mount these in ceiling-suspended positions as well. Our floor and ductless air conditioning ceiling mount mini split systems are equipped with digital frequency control for automatic capacity adjustments, convenient remote controller, automatic air sweeping louvers, cooling, heating, dehumidification, ventilation modes, and with fresh air intake options. Check out our selection of floor-ceiling flex mount ductless mini splits!\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMini Split Includes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit\u003c\/li\u003e\n\u003cli\u003eOutdoor Unit\u003c\/li\u003e\n\u003cli\u003eWireless Remote Control\u003c\/li\u003e\n\u003cli\u003eVarious Installation Kit Options Available\u003c\/li\u003e\n\u003cli\u003eFlare Connection Leak Guard Sealer\u003c\/li\u003e\n\u003cli\u003eInstallation Manual\u003c\/li\u003e\n\u003cli\u003eUser’s Manual\u003c\/li\u003e\n\u003cli\u003eManufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFeatures\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eUltra High Efficiency\u003c\/strong\u003e Inverter++ floor\/ceiling split heat pump system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCooling capacity: \u003cstrong\u003e18,000 BTU\/H\u003c\/strong\u003e with \u003cstrong\u003e20.0 SEER\u003c\/strong\u003e efficiency\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating capacity: \u003cstrong\u003e18,000 BTU\/H\u003c\/strong\u003e with \u003cstrong\u003e10.5 HSPF \u003c\/strong\u003eefficiency\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage: \u003cstrong\u003e208~230 V, 60 Hertz, 1 Ph\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloor\/Ceiling Flex Mount\u003c\/strong\u003e Air Conditioning \u0026amp; Heating System\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVariable Speed \u003cstrong\u003eDC Inverter\u003c\/strong\u003e Operation Mode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable length\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecopper line set with flare connections\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAHRI Estimated Annual Operating Costs: \u003c\/span\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eCooling:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e$113.00 \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeating:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e$346.00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Desk Control\u003c\/strong\u003e\u003cbr\u003eWith a smart control board, Pioneer air conditioners can be turned on\/off via long distance control signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003e46° F Heating\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eRefrigerant Leakage Detect\u003c\/strong\u003e \u003cbr\u003eIndoor unit shows error code \"EC\" and stops automatically when refrigerant leakage is detected. This protects the compressor from high temperature damage due to refrigerant leakage.\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eAnti-cold Air Function\u003c\/strong\u003e \u003cbr\u003eIndoor fan speed is regulated automatically from the lowest grade to the setting grade according to evaporator temperature when the unit just starts heating operation. This function can prevent cold air blowing out to avoid discomfort to the users.\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eEmergency Using\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eLow Ambient Cooling\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003eWith built-in low ambient kit or special designed PCB, outdoor fan speeds can be changed automatically according to condensation temperature. The system can run heating operation even when the outdoor ambient temperature is down to -13°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eFollow Me\u003c\/strong\u003e \u003cbr\u003eTemperature sensor built in the remote controller will sense it’s surrounding temperature. The unit will adjust the room temperature more accurately to give you comfort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptional\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWired Controller\u003cbr\u003e\u003c\/strong\u003eCompared with infrared remote controller, wired controller can be fixed on the wall and makes air conditioner control more convenient.\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eRemote in Engineer Mode\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003e\u003c\/i\u003e\u003cstrong\u003eCentral Control Management\u003cbr\u003e\u003c\/strong\u003eThe centralized controller is a multi-functional device that can control up to 64 indoor units within a maximum connection length of 3.90 Ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-w22m{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-8c31{background-color:#ffffff;border-color:#000000;color:#000000;text-align:left;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-w22m\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: bold;\"\u003ePerformance Data\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e208~230V, 60Hz, 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eCooling Rated Capacity\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eCooling Capacity Range\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e7,500~24,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eCooling SEER\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e20.0 BTU\/w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eHeating Rated Capacity\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eHeating Capacity Range\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e7,500~24,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eHeating HSPF4\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e10.5 BTU\/w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eSuitable Area\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e250~450 Sq.F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCondenser\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eSound Level\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e60.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eNet Dimensions (WDH)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e33.3\" W x 14.4\" D x 27.6\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eCarton Dimensions (WDH)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e38.0\" W x 15.5\" D x 29.8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e95 \/ 103 Lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eCool Mode - Outdoor Operating Temperature Range\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e5° to 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eHeat Mode - Outdoor Operating Temperature Range\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e-13° to 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eAir Handler\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eAir Flow (Hi\/Med\/Lo)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e578 \/ 520 \/ 465 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eSound Level (Hi\/Med\/Lo)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e47.0 \/ 44.0 \/ 39.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eNet Dimensions (WDH)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e42.0 \" W x 26.5\" D x 9.3\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eCarton Dimensions (WDH)\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e45.0\" W x 29.8\" D x 12.4\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-w22m\"\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd class=\"tg-8c31\"\u003e55 \/ 66 Lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eINSTALLATION \u0026amp; GUIDES\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.pdhvac.com\/site\/downloads\/UYB-22.pdf\" target=\"_blank\"\u003eTechnical Brochure\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.pdhvac.com\/site\/downloads\/UYB_UM.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.pdhvac.com\/site\/downloads\/UYB_IM.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.pdhvac.com\/site\/downloads\/LCAC_22_SM.pdf\" target=\"_blank\"\u003eService Manual\u003c\/a\u003e\u003ca href=\"https:\/\/www.pdhvac.com\/site\/downloads\/UYB-22.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Performance:\u003c\/strong\u003e 18,000 BTU with a \u003cstrong\u003e20 SEER\u003c\/strong\u003e rating provides solid cooling and heating for medium to large spaces, while minimizing energy consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e The floor\/ceiling mount design allows for versatile placement, making it ideal for spaces with unique layouts or when wall-mounted units aren't feasible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMid-Length Line Sets:\u003c\/strong\u003e Includes \u003cstrong\u003e16 ft. line sets\u003c\/strong\u003e, providing flexibility for medium-sized spaces with moderate installation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet \u0026amp; Efficient:\u003c\/strong\u003e Features advanced noise-reduction technology to ensure quiet operation, offering comfort without disruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Year-Round Comfort:\u003c\/strong\u003e Provides cooling in summer and heating in winter, ensuring year-round climate control with efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the Pioneer 18,000 BTU 20 SEER Floor\/Ceiling Mini-Split Air Conditioner Heat Pump System?\u003c\/strong\u003e\u003cbr\u003eA: This mini-split system provides both cooling and heating with a 20 SEER rating. Its floor\/ceiling design allows for flexible installation, ensuring efficient airflow and temperature distribution. It comes with 16 ft. line sets for convenient setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the floor\/ceiling design improve the system’s performance?\u003c\/strong\u003e\u003cbr\u003eA: The floor\/ceiling design allows the system to be installed in various positions, enhancing airflow and promoting even cooling and heating throughout the room. This configuration is ideal for spaces where traditional wall units are not suitable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What room size is this system suitable for?\u003c\/strong\u003e\u003cbr\u003eA: This system is suitable for rooms up to 750 sq. ft., offering effective climate control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for residential use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this system is ideal for residential spaces, providing efficient and quiet cooling and heating with minimal energy consumption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require professional installation?\u003c\/strong\u003e\u003cbr\u003eA: While the unit comes with 16 ft. line sets, professional installation is recommended to ensure optimal performance and reliability.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean Filters Every 2-4 Weeks\u003c\/strong\u003e: Remove dust and dirt from filters to maintain proper airflow and efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean Coils Annually\u003c\/strong\u003e: Prevent dirt buildup on evaporator and condenser coils to keep the system running smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Refrigerant Levels\u003c\/strong\u003e: Ensure proper refrigerant levels for optimal cooling and heating performance; contact a technician if necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnsure Proper Drainage\u003c\/strong\u003e: Regularly inspect and clean the condensate drain to avoid clogs and prevent mold growth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintain Outdoor Unit\u003c\/strong\u003e: Keep the outdoor unit clear of debris to ensure unobstructed airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchedule Professional Maintenance\u003c\/strong\u003e: Have a technician perform an annual inspection to ensure the system runs efficiently and to detect potential issues early.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pioneer","offers":[{"title":"Default Title","offer_id":46470389268705,"sku":"UYB018GMFILCAD-16","price":1638.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/main-18-24_661d0319-4586-42d5-bee0-d6ce4438777a.jpg?v=1747296518","url":"https:\/\/sportsteez.com\/products\/pioneer-18-000-btu-20-seer-floor-ceiling-mini-split-air-conditioner-heat-pump-system-with-16-ft-line-sets-uyb018gmfilcad-16","provider":"EP","version":"1.0","type":"link"}