{"product_id":"schulz-smh-40-refrigerated-air-dryer-high-temperature-non-cycling-40-cfm-115v-single-phase-new","title":"Schulz SMH-40 Refrigerated Air Dryer High Temperature Non-Cycling 40 CFM 115V Single Phase New - SMH-040-UP-TD","description":"\u003ch2\u003eSchulz SMH-40 Refrigerated Air Dryer High Temperature Non-Cycling 40 CFM 115V Single Phase New - SMH-040-UP-TD\u003c\/h2\u003e\n\u003cp\u003eSchulz high-temperature dryers are designed for high inlet (up to 194°F) and room temperature applications (up to 113°F). SMH High Temp Dryers eliminate the need for separate aftercooler and moisture separators, conserving valuable floor space. Its innovative cooling system delivers high performance and energy savings. The integrated digital controller and automatic drain ensure stable dew point during operation. Removable panels facilitate easy and quick access to internal components.\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:750c326d-fb1a-4fa6-bc93-31b37e9210d9-32\" data-testid=\"conversation-turn-66\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"29492820-e5a5-4118-9de1-7429e6562a06\" dir=\"auto\" data-message-model-slug=\"gpt-5-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cul data-start=\"27\" data-end=\"1758\"\u003e\n\u003cli data-section-id=\"14vpsjc\" data-start=\"27\" data-end=\"378\"\u003e\n\u003cp data-start=\"29\" data-end=\"378\"\u003e\u003cstrong data-start=\"29\" data-end=\"66\"\u003eHigh‑Temperature Moisture Control\u003c\/strong\u003e – The \u003cstrong data-start=\"73\" data-end=\"158\"\u003eSchulz SMH‑40 Refrigerated Air Dryer High Temperature Non‑Cycling (SMH‑040‑UP‑TD)\u003c\/strong\u003e is engineered to \u003cstrong data-start=\"176\" data-end=\"220\" data-is-only-node=\"\"\u003edry compressed air up to 40 CFM reliably\u003c\/strong\u003e, even with \u003cstrong data-start=\"232\" data-end=\"268\"\u003einlet temperatures up to ~194 °F\u003c\/strong\u003e, eliminating the need for a separate aftercooler or moisture separator. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1i02znc\" data-start=\"380\" data-end=\"674\"\u003e\n\u003cp data-start=\"382\" data-end=\"674\"\u003e\u003cstrong data-start=\"382\" data-end=\"425\"\u003eIntegrated Drying + Aftercooling System\u003c\/strong\u003e – Its \u003cstrong data-start=\"432\" data-end=\"485\"\u003ebuilt‑in aftercooler circuit with automatic drain\u003c\/strong\u003e and \u003cstrong data-start=\"490\" data-end=\"516\" data-is-only-node=\"\"\u003edigital DMC controller\u003c\/strong\u003e ensure a stable dew point and consistent performance without extra equipment, saving installation and maintenance time. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1echb7o\" data-start=\"676\" data-end=\"959\"\u003e\n\u003cp data-start=\"678\" data-end=\"959\"\u003e\u003cstrong data-start=\"678\" data-end=\"718\"\u003eEnergy‑Efficient and Quiet Operation\u003c\/strong\u003e – The refrigeration system delivers \u003cstrong data-start=\"755\" data-end=\"808\"\u003eefficient heat rejection with lower pressure drop\u003c\/strong\u003e and runs at \u003cstrong data-start=\"821\" data-end=\"840\" data-is-only-node=\"\"\u003eunder ~70 dB(A)\u003c\/strong\u003e sound levels — ideal for workshops or compressed air systems in confined spaces. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gn5hsy\" data-start=\"961\" data-end=\"1203\"\u003e\n\u003cp data-start=\"963\" data-end=\"1203\"\u003e\u003cstrong data-start=\"963\" data-end=\"995\"\u003eCompact, Easy‑Service Design\u003c\/strong\u003e – With \u003cstrong data-start=\"1003\" data-end=\"1062\"\u003eremovable access panels and a 115 V, single‑phase setup\u003c\/strong\u003e, it integrates into existing compressor systems with minimal fuss and easy filter or component access. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10f20o1\" data-start=\"1205\" data-end=\"1462\"\u003e\n\u003cp data-start=\"1207\" data-end=\"1462\"\u003e\u003cstrong data-start=\"1207\" data-end=\"1244\"\u003eConsistent Performance Under Load\u003c\/strong\u003e – Designed for \u003cstrong data-start=\"1260\" data-end=\"1297\"\u003econtinuous, non‑cycling operation\u003c\/strong\u003e, it keeps drying performance steady — especially useful in systems where compressors run long cycles or supply multiple tools. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"iws22z\" data-start=\"1464\" data-end=\"1758\"\u003e\n\u003cp data-start=\"1466\" data-end=\"1758\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1484\"\u003eExpert Verdict\u003c\/strong\u003e – A \u003cstrong data-start=\"1489\" data-end=\"1536\"\u003erobust and efficient refrigerated air dryer\u003c\/strong\u003e that simplifies moisture management for medium compressed air systems — providing \u003cstrong data-start=\"1619\" data-end=\"1689\" data-is-only-node=\"\"\u003estable dry air, reduced corrosion risk, and improved tool lifespan\u003c\/strong\u003e without extra floor equipment. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"110\" data-end=\"505\"\u003e\u003cstrong data-start=\"110\" data-end=\"158\"\u003eQ: What is the Schulz SMH‑40 dryer used for?\u003c\/strong\u003e\u003cbr data-start=\"158\" data-end=\"161\"\u003eA: It’s a \u003cstrong data-start=\"171\" data-end=\"225\"\u003ehigh‑temperature refrigerated compressed air dryer\u003c\/strong\u003e that removes moisture from compressor discharge air to protect tools, pneumatic systems, and paint\/coating operations from rust, water damage, and inconsistent airflow. It eliminates the need for separate aftercooler and moisture separators. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"507\" data-end=\"725\"\u003e\u003cstrong data-start=\"507\" data-end=\"555\"\u003eQ: How much airflow capacity does it handle?\u003c\/strong\u003e\u003cbr data-start=\"555\" data-end=\"558\"\u003eA: Rated for \u003cstrong data-start=\"571\" data-end=\"604\"\u003e40 CFM of compressed air flow\u003c\/strong\u003e, suitable for medium‑duty compressor systems in workshops and industrial settings. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"727\" data-end=\"942\"\u003e\u003cstrong data-start=\"727\" data-end=\"771\"\u003eQ: What power requirements does it have?\u003c\/strong\u003e\u003cbr data-start=\"771\" data-end=\"774\"\u003eA: Runs on \u003cstrong data-start=\"785\" data-end=\"815\"\u003e115 V single‑phase (60 Hz)\u003c\/strong\u003e power and draws about \u003cstrong data-start=\"838\" data-end=\"847\"\u003e4.7 A\u003c\/strong\u003e — compatible with standard workshop electrical circuits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"944\" data-end=\"1279\"\u003e\u003cstrong data-start=\"944\" data-end=\"1001\"\u003eQ: What features improve performance and convenience?\u003c\/strong\u003e\u003cbr data-start=\"1001\" data-end=\"1004\"\u003eA: It includes a \u003cstrong data-start=\"1021\" data-end=\"1078\"\u003ebuilt‑in aftercooler circuit with separate auto drain\u003c\/strong\u003e, \u003cstrong data-start=\"1080\" data-end=\"1130\"\u003eDMC electronic controller with digital display\u003c\/strong\u003e, \u003cstrong data-start=\"1132\" data-end=\"1162\"\u003elower pressure drop design\u003c\/strong\u003e, and \u003cstrong data-start=\"1168\" data-end=\"1199\"\u003equiet operation (\u0026lt;70 dB(A))\u003c\/strong\u003e for reliable, low‑noise moisture removal. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1281\" data-end=\"1537\"\u003e\u003cstrong data-start=\"1281\" data-end=\"1321\"\u003eQ: Can it handle hot compressed air?\u003c\/strong\u003e\u003cbr data-start=\"1321\" data-end=\"1324\"\u003eA: Yes — engineered for \u003cstrong data-start=\"1348\" data-end=\"1397\"\u003ehigh inlet temperatures up to ~194 °F (90 °C)\u003c\/strong\u003e and ambient conditions up to ~113 °F (45 °C), removing moisture without additional cooling equipment. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1539\" data-end=\"1742\"\u003e\u003cstrong data-start=\"1539\" data-end=\"1588\"\u003eQ: What connections and refrigerant are used?\u003c\/strong\u003e\u003cbr data-start=\"1588\" data-end=\"1591\"\u003eA: Uses \u003cstrong data-start=\"1599\" data-end=\"1632\"\u003e1\/2″ NPT‑F inlet\/outlet ports\u003c\/strong\u003e and \u003cstrong data-start=\"1637\" data-end=\"1658\"\u003eR134a refrigerant\u003c\/strong\u003e for efficient cooling and drying performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1744\" data-end=\"1930\"\u003e\u003cstrong data-start=\"1744\" data-end=\"1771\"\u003eQ: How big is the unit?\u003c\/strong\u003e\u003cbr data-start=\"1771\" data-end=\"1774\"\u003eA: Measures about \u003cstrong data-start=\"1792\" data-end=\"1817\"\u003e16.8″ × 16.4″ × 25.6″\u003c\/strong\u003e and weighs ~\u003cstrong data-start=\"1830\" data-end=\"1839\"\u003e75 lb\u003c\/strong\u003e, making it compact enough for workshop installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1932\" data-end=\"2157\"\u003e\u003cstrong data-start=\"1932\" data-end=\"1965\"\u003eQ: Who should use this dryer?\u003c\/strong\u003e\u003cbr data-start=\"1965\" data-end=\"1968\"\u003eA: Ideal for \u003cstrong data-start=\"1981\" data-end=\"2045\"\u003eworkshops, garages, industrial plants, and pneumatic systems\u003c\/strong\u003e where consistent dry air is essential for tool performance and longevity.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1z0ntg4\" data-start=\"236\" data-end=\"493\"\u003e\n\u003cp data-start=\"238\" data-end=\"493\"\u003e\u003cstrong data-start=\"238\" data-end=\"276\"\u003eVerify Condensate Drain Operation:\u003c\/strong\u003e Check that the built‑in automatic drain and aftercooler drain operate freely and aren’t clogged; proper drainage prevents water carry‑over and helps maintain dew point control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xwf58r\" data-start=\"494\" data-end=\"715\"\u003e\n\u003cp data-start=\"496\" data-end=\"715\"\u003e\u003cstrong data-start=\"496\" data-end=\"531\"\u003eClean Condenser \u0026amp; Air Passages:\u003c\/strong\u003e Periodically remove dust and debris from the condenser fins and ventilation openings to support effective heat rejection and drying efficiency. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hcrdk3\" data-start=\"716\" data-end=\"877\"\u003e\n\u003cp data-start=\"718\" data-end=\"877\"\u003e\u003cstrong data-start=\"718\" data-end=\"758\"\u003eKeep Inlet\/Outlet Connections Clear:\u003c\/strong\u003e Inspect air fittings and hoses for blockages or leaks — clean or replace to preserve airflow and pressure stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z109do\" data-start=\"878\" data-end=\"1130\"\u003e\n\u003cp data-start=\"880\" data-end=\"1130\"\u003e\u003cstrong data-start=\"880\" data-end=\"911\"\u003eMonitor Digital Controller:\u003c\/strong\u003e Regularly check the electronic controller display for temperature\/dew point readings and any error codes; stable readings help ensure the dryer operates within design parameters. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mdrmkj\" data-start=\"1131\" data-end=\"1315\"\u003e\n\u003cp data-start=\"1133\" data-end=\"1315\"\u003e\u003cstrong data-start=\"1133\" data-end=\"1164\"\u003eMaintain Clean Environment:\u003c\/strong\u003e Install the dryer in a dust‑free, ventilated space with clearance around it to prevent heat buildup and allow airflow through coils and electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cd3jpl\" data-start=\"1316\" data-end=\"1479\"\u003e\n\u003cp data-start=\"1318\" data-end=\"1479\"\u003e\u003cstrong data-start=\"1318\" data-end=\"1348\"\u003ePower Down Before Service:\u003c\/strong\u003e Always shut off power and relieve system air pressure before cleaning, inspecting connections, or servicing the unit for safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schulz","offers":[{"title":"Default Title","offer_id":45483031429299,"sku":"SMH-040-UP-TD","price":4072.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/2943\/3011\/files\/Secador-Schulz-High-Temperature-1742831887081_a6bd5cf8-8ebc-4fe1-af0b-d9d6012ef9eb.png?v=1777547363","url":"https:\/\/sportsteez.com\/products\/schulz-smh-40-refrigerated-air-dryer-high-temperature-non-cycling-40-cfm-115v-single-phase-new","provider":"Sportsteez","version":"1.0","type":"link"}