{"product_id":"tuttnauer-2340m-manual-autoclave-mfi-ttn-2340m","title":"Tuttnauer 2340M Manual Autoclave - MFI-TTN-2340M","description":"\u003cdiv class=\"accordion-single js-acc-single\" id=\"Description\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item is-open\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003ch2\u003eTuttnauer 2340M Manual Autoclave - MFI-TTN-2340M\u003c\/h2\u003e\n\u003cp\u003eThe Tuttnauer 2340M Manual Autoclave provides quick instrument turnaround for high volume labs and clinics. It will compliment any healthcare facility and satisfy all of your sterilization needs.\u003c\/p\u003e\n\u003cp\u003eAll certified autoclaves include a power cable and new preventative maintenance kit installed, which includes a new gasket and filters. We also perform a complete calibration to manufacturer specifications, spore test, and complete flush of the system.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe versatile 2340M is the smaller model in the M Series by Tuttnauer. It is an efficient, space-saving powerhouse. It features a chamber size of 9\" x 18\" and a chamber volume of 5 gallons (19 L), compared to the 2540M M Series which has a chamber size of 10\" x 19\" and volume of 6 gallons.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eM Series autoclaves are primarily used by veterinarians or surgeons but are also used in a range of other settings, including active surgery centers, medical practices, dental offices, schools, doctor's clinics, or tattoo establishments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Features\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eFeatures\u003c\/h5\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cul\u003e\n\u003cli\u003eReliable and durable.\u003c\/li\u003e\n\u003cli\u003eBright, easy to use panel was designed with the operator in mind.\u003c\/li\u003e\n\u003cli\u003eSpeed and reliability without compromising on load size.\u003c\/li\u003e\n\u003cli\u003eAutomatic shut off at the end of both the sterilization and dry cycles to protect against overheating.\u003c\/li\u003e\n\u003cli\u003eInsufficient water detector.\u003c\/li\u003e\n\u003cli\u003eA long life electro polished chamber and door are made to last.\u003c\/li\u003e\n\u003cli\u003e316L stainless steel chamber.\u003c\/li\u003e\n\u003cli\u003eDouble safety locking device prevents the door from opening while the chamber is pressurized.\u003c\/li\u003e\n\u003cli\u003eDrain valve is located on the front, allowing for quick and easy draining of water reservoir.\u003c\/li\u003e\n\u003cli\u003eDual safety thermostat to protect against overheating.\u003c\/li\u003e\n\u003cli\u003eDesigned to meet the most current sterilization standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eSpecifications\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Specifications\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eChamber Dimensions\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003e9\" x 18\" (230 mm x 470 mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eChamber Volume\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e5 gallons (19 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e21.5\" (D) x 20\" (W) x 14.4\" (H) (545 mm x 510 mm x 365 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNumber of Trays\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eTray Dimensions\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e16.3\" (D) x 6.7\" (W) x 0.8\" (H) (415 mm x 170 mm x 20 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStandard Cassette Capacity\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e2 full and 2 half\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStandard Full Size Cassette\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8\" x 11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStandard Half Size Cassette\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8\" x 5.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStandard Unwrapped Cycle Time (Cold)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e27 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStandard Unwrapped Cycle Time (Hot)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e13 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCurrent\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e12 A(failure to incorporate will void your warranty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Accessories\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eAccessories\u003c\/h5\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cp\u003eThe following accessories are compatible and commonly purchased with the 2340M Manual Autoclave:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChamber Brite Powdered Autoclave Cleaner:\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e#CB0010-1:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBox (10 Packets).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CB0010:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCase (120 Packets).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eClean \u0026amp; Simple Ultrasonic\/Enzymatic Tablets:\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e#CS0144-1:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBox of 144.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CS0064:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCase of 768.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CS0144:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCase of 1728.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eClean \u0026amp; Simple Ultrasonic Cleaner:\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU1:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.85 gallon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU1BK:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.85 gallon with Basket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU1H:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.85 gallon with Heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU1HBK:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.85 gallon with Heater and Basket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU3:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.25 gallon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU3BK:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.25 gallon with Basket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU3H:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.25 gallon with Heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU3HBK:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.25 gallon with Heater and Basket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU6:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e6.5 gallon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU6BK:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e6.5 gallon with Basket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU6H:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e6.5 gallon with Heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#CSU6HBK:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e6.5 gallon with Heater and Basket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#DS1000:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSteam Distiller Purification System.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Literature\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eLiterature\u003c\/h5\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1046\/1086\/files\/Tuttnauer-Table-Top-Line-Autoclaves-and-Accessories-Catalog.pdf\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\" target=\"_blank\"\u003eTuttnauer Table Top Line Autoclaves and Accessories Catalog\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1046\/1086\/files\/Tuttnauer-Manual-Autoclaves-Weekly-Cleaning-and-Maintenance-Instructions.pdf\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\" target=\"_blank\"\u003eTuttnauer Manual Autoclaves - Weekly Cleaning and Maintenance Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1046\/1086\/files\/Tuttnauer-Operation-And-Maintenance-Manual-Tabletop-Autoclaves.pdf\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\" target=\"_blank\"\u003eTuttnauer Operation And Maintenance Manual - Tabletop Autoclaves\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"30\" data-end=\"186\"\u003e\n\u003cstrong data-start=\"32\" data-end=\"61\"\u003eReliable Manual Operation\u003c\/strong\u003e – Offers full manual control for those who prefer a hands-on approach to sterilization, ensuring precise cycle management.\u003c\/li\u003e\n\u003cli data-start=\"187\" data-end=\"339\"\u003e\n\u003cstrong data-start=\"189\" data-end=\"214\"\u003eCompact Yet Efficient\u003c\/strong\u003e – Perfect for small to medium-sized facilities, providing a high level of sterilization without taking up excessive space.\u003c\/li\u003e\n\u003cli data-start=\"340\" data-end=\"466\"\u003e\n\u003cstrong data-start=\"342\" data-end=\"368\"\u003eDurable \u0026amp; Long-Lasting\u003c\/strong\u003e – Constructed with high-quality, corrosion-resistant materials to withstand years of heavy use.\u003c\/li\u003e\n\u003cli data-start=\"467\" data-end=\"596\"\u003e\n\u003cstrong data-start=\"469\" data-end=\"490\"\u003eQuick Cycle Times\u003c\/strong\u003e – Provides efficient sterilization cycles, making it ideal for environments with high throughput needs.\u003c\/li\u003e\n\u003cli data-start=\"597\" data-end=\"740\"\u003e\n\u003cstrong data-start=\"599\" data-end=\"612\"\u003eVersatile\u003c\/strong\u003e – Suitable for sterilizing a variety of instruments, from dental tools to laboratory equipment, ensuring maximum flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"0\" data-end=\"300\"\u003e\u003cstrong data-start=\"0\" data-end=\"52\"\u003eQ: What is the Tuttnauer 2340M Manual Autoclave?\u003c\/strong\u003e\u003cbr data-start=\"52\" data-end=\"55\"\u003eA: The Tuttnauer 2340M is a manual autoclave designed for sterilization in medical, dental, and laboratory environments. It uses steam to efficiently sterilize instruments, providing reliability and performance for smaller to medium-sized loads.\u003c\/p\u003e\n\u003cp data-start=\"302\" data-end=\"519\"\u003e\u003cstrong data-start=\"302\" data-end=\"353\"\u003eQ: What is the capacity of the Tuttnauer 2340M?\u003c\/strong\u003e\u003cbr data-start=\"353\" data-end=\"356\"\u003eA: The 2340M has a chamber capacity of 3.5 gallons (13.2 liters), ideal for sterilizing medical instruments, dental tools, and lab equipment in smaller quantities.\u003c\/p\u003e\n\u003cp data-start=\"521\" data-end=\"780\"\u003e\u003cstrong data-start=\"521\" data-end=\"564\"\u003eQ: How is the Tuttnauer 2340M operated?\u003c\/strong\u003e\u003cbr data-start=\"564\" data-end=\"567\"\u003eA: The 2340M is a manual autoclave, meaning the user must manually set the sterilization cycle, which provides precise control over the process. The autoclave has simple, user-friendly controls for easy operation.\u003c\/p\u003e\n\u003cp data-start=\"782\" data-end=\"1024\"\u003e\u003cstrong data-start=\"782\" data-end=\"838\"\u003eQ: What are the key features of the Tuttnauer 2340M?\u003c\/strong\u003e\u003cbr data-start=\"838\" data-end=\"841\"\u003eA: Key features include a manual control system, automatic shut-off after the cycle is completed, a durable stainless steel chamber, and a safety valve to prevent over-pressurization.\u003c\/p\u003e\n\u003cp data-start=\"1026\" data-end=\"1254\"\u003e\u003cstrong data-start=\"1026\" data-end=\"1073\"\u003eQ: Is the Tuttnauer 2340M easy to maintain?\u003c\/strong\u003e\u003cbr data-start=\"1073\" data-end=\"1076\"\u003eA: Yes, the Tuttnauer 2340M is designed for easy maintenance. Regular cleaning of the chamber and checking of seals are necessary to keep the autoclave in good working condition.\u003c\/p\u003e\n\u003cp data-start=\"1256\" data-end=\"1482\"\u003e\u003cstrong data-start=\"1256\" data-end=\"1317\"\u003eQ: What safety features does the Tuttnauer 2340M include?\u003c\/strong\u003e\u003cbr data-start=\"1317\" data-end=\"1320\"\u003eA: The autoclave is equipped with an over-temperature safety mechanism, a pressure relief valve, and automatic shut-off for enhanced user safety during operation.\u003c\/p\u003e\n\u003cp data-start=\"1484\" data-end=\"1686\"\u003e\u003cstrong data-start=\"1484\" data-end=\"1531\"\u003eQ: Who is the Tuttnauer 2340M designed for?\u003c\/strong\u003e\u003cbr data-start=\"1531\" data-end=\"1534\"\u003eA: It is ideal for medical and dental offices, small clinics, and laboratories that require reliable and compact sterilization of instruments and tools.\u003c\/p\u003e\n\u003cp data-start=\"1688\" data-end=\"1962\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"1688\" data-end=\"1755\"\u003eQ: What type of sterilization does the Tuttnauer 2340M provide?\u003c\/strong\u003e\u003cbr data-start=\"1755\" data-end=\"1758\"\u003eA: The 2340M uses steam sterilization, which is effective for sterilizing a wide range of items, including metal, glass, and certain types of plastic instruments that can withstand high heat and pressure.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"76\" data-end=\"239\"\u003e\n\u003cstrong data-start=\"79\" data-end=\"100\"\u003eRegular Cleaning:\u003c\/strong\u003e Clean the chamber, trays, and door seal after each use using a soft cloth and mild detergent to prevent residue buildup and contamination.\u003c\/li\u003e\n\u003cli data-start=\"240\" data-end=\"401\"\u003e\n\u003cstrong data-start=\"243\" data-end=\"269\"\u003eInspect the Door Seal:\u003c\/strong\u003e Check the door seal for any cracks or wear. Replace the seal if necessary to ensure a proper seal during the sterilization process.\u003c\/li\u003e\n\u003cli data-start=\"402\" data-end=\"598\"\u003e\n\u003cstrong data-start=\"405\" data-end=\"419\"\u003eDescaling:\u003c\/strong\u003e Perform descaling as needed, especially if using hard water. Follow the manufacturer’s instructions for proper descaling procedures to prevent mineral buildup inside the chamber.\u003c\/li\u003e\n\u003cli data-start=\"599\" data-end=\"761\"\u003e\n\u003cstrong data-start=\"602\" data-end=\"620\"\u003eWater Quality:\u003c\/strong\u003e Use distilled or deionized water to reduce mineral deposits that could affect performance and lead to premature wear of internal components.\u003c\/li\u003e\n\u003cli data-start=\"762\" data-end=\"919\"\u003e\n\u003cstrong data-start=\"765\" data-end=\"794\"\u003eCheck the Pressure Gauge:\u003c\/strong\u003e Regularly monitor the pressure gauge and ensure it’s functioning correctly. Calibration may be needed for accurate readings.\u003c\/li\u003e\n\u003cli data-start=\"920\" data-end=\"1089\"\u003e\n\u003cstrong data-start=\"923\" data-end=\"950\"\u003eLubricate Moving Parts:\u003c\/strong\u003e Apply a non-oily lubricant to any moving parts, such as the door mechanism or valves, to ensure smooth operation and prevent rust or wear.\u003c\/li\u003e\n\u003cli data-start=\"1090\" data-end=\"1276\"\u003e\n\u003cstrong data-start=\"1093\" data-end=\"1129\"\u003eDrain and Clean Water Reservoir:\u003c\/strong\u003e Empty and clean the water reservoir regularly to prevent bacterial growth or mineral buildup. Refill with fresh distilled water before each cycle.\u003c\/li\u003e\n\u003cli data-start=\"1277\" data-end=\"1422\"\u003e\n\u003cstrong data-start=\"1280\" data-end=\"1300\"\u003eCheck for Leaks:\u003c\/strong\u003e Inspect the door, vents, and seals for any signs of leaks. Address any leaks immediately to avoid sterilization failures.\u003c\/li\u003e\n\u003cli data-start=\"1423\" data-end=\"1567\"\u003e\n\u003cstrong data-start=\"1426\" data-end=\"1446\"\u003eRun Test Cycles:\u003c\/strong\u003e Perform routine sterilization and vacuum tests to ensure the autoclave is reaching the desired temperature and pressure.\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1749\"\u003e\n\u003cstrong data-start=\"1572\" data-end=\"1595\"\u003eAnnual Maintenance:\u003c\/strong\u003e Have the autoclave serviced by a professional annually to ensure all internal components are functioning properly and to extend the lifespan of the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tuttnauer","offers":[{"title":"Default Title","offer_id":46503620149473,"sku":"MFI-TTN-2340M","price":2813.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/tuttnauer-3870m-large-capacity-manual-autoclave_grande_7_ba7d667b-7a35-479c-8440-48ecad588e5e.jpg?v=1748339756","url":"https:\/\/sportsteez.com\/products\/tuttnauer-2340m-manual-autoclave-mfi-ttn-2340m","provider":"EP","version":"1.0","type":"link"}