{"product_id":"tuttnauer-3870hsg-ws-pre-and-post-vacuum-autoclave-ttn-3870hsg-ws-230-d","title":"Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave - TTN-3870HSG-WS-230-D","description":"\u003ch2\u003eTuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave - TTN-3870HSG-WS-230-D\u003c\/h2\u003e\n\u003cp\u003eThe Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave is an 85 liter autoclave sterilizer that's designed for large clinics and ASC's. It produces hospital grade sterilization with a medium load capacity, and is most ideal for medical clinics, dental clinics, and operating rooms.\u003c\/p\u003e\n\u003cp\u003eAs the name suggests, the Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave contains a built-in vacuum system designed for fractionated pre vacuum air removal and post vacuum drying. This removes air pockets from the chamber to ensure full steam sterilization on the entire load. The post vacuum process dries the load efficiently for a bone-dry finish.\u003c\/p\u003e\n\u003cp\u003eThe HSG-WS model specifically has been designed for water saving, through an efficient recycling system. In total, it will utilize only five liters of tap water per day. In terms of utility connection, it can be hooked up to existing utilities for distilled water, tap water, and electricity, or can be independent of utilities with only a power connection needed. With the independence feature, the water reservoirs must be manually filled prior to cycles.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003eTechnical Standards and Compliance\u003c\/p\u003e\n\u003cp\u003eThe Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave fulfills the following directives and standards:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuality Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eISO 9001:2015 - Quality Management Systems.\u003cbr\u003eEN ISO 13485:2016 Quality Management System – Medical Devices.\u003cbr\u003eIn compliance with 21 CFR part 820 \u0026amp; part 11.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDirectives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMDD 93\/42\/EEC amended in Directive 2007\/47\/EEC.\u003cbr\u003ePED 2014\/68\/EU - Pressure Equipment Directive.\u003cbr\u003e2012\/19\/EU WEEE and 2017\/2102 RoHS.\u003c\/p\u003e\n\u003ch5\u003eTechnical Standards\u003c\/h5\u003e\n\u003cp\u003eEN 285: 2015 Large steam sterilizer.\u003cbr\u003eEN 61010-1: 2010.\u003cbr\u003eEN 61326-1: 2013.\u003cbr\u003eEN 61010-2-40: 2015.\u003cbr\u003eFDA Approved.\u003cbr\u003eANSI\/AAMI\/ST8:2013 (R2018).\u003cbr\u003eANSI\/AAMI - ST55:2016.\u003cbr\u003eASME Code section I and section VIII. Div.I.\u003cbr\u003eFor medical clinics, dental clinics, and operating rooms.\u003cbr\u003eBuilt-in vacuum system designed for pre vacuum air removal and post vacuum drying.\u003cbr\u003eUses up to five liters of tap water per day.\u003cbr\u003eCan be connected to utilities for water, or stand independent and be manually filled with water.\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-gvcd{background-color:#ffffff;border-color:#000000;color:#000000;text-align:left;vertical-align:top}\n.tg .tg-oevy{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable style=\"width: 100%;\" class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eions\u003c\/th\u003e\n\u003cth style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e15.2\" x 29.9\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eChamber Volume\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e85 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eNumber of Trays\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eTray Dimensions (Small)\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e11.3\" x 1\" x 26.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eTray Dimensions (Large)\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e13.8\" x 1\" x 26.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e28.4\" x 53.8\" x 46.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eAutoclave Weight\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e397 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003eVoltage\/Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e3 ph, 230 Volts, 25 Volts, 25 Amp., 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.7086%;\" class=\"tg-oevy\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 60.2914%;\" class=\"tg-gvcd\"\u003e9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced Pre \u0026amp; Post Vacuum Technology – Ensures complete air removal and effective sterilization, even for complex and porous loads.\u003c\/li\u003e\n\u003cli\u003eHigh-Volume Capability – Ideal for busy medical and dental practices, with a large chamber that accommodates a variety of instruments.\u003c\/li\u003e\n\u003cli\u003eReliable Performance – Offers consistent, efficient sterilization with minimal cycle times, enhancing workflow productivity.\u003c\/li\u003e\n\u003cli\u003eUser-Friendly – Equipped with a clear digital display and intuitive controls, making operation straightforward for all users.\u003c\/li\u003e\n\u003cli\u003eDurable \u0026amp; Long-Lasting – Built with high-quality materials to provide long-term reliability and minimal maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How does the pre- and post-vacuum work on the Tuttnauer 3870HSG-WS?\u003cbr\u003eA: The pre-vacuum removes air from the chamber before the sterilization process, ensuring that steam can penetrate the packaging of instruments. The post-vacuum cycle expels remaining air after sterilization to help dry instruments thoroughly, enhancing the overall sterilization outcome.\u003c\/li\u003e\n\u003cli\u003eQ: What is the capacity of the Tuttnauer 3870HSG-WS?\u003cbr\u003eA: The Tuttnauer 3870HSG-WS has a large chamber capacity suitable for sterilizing a wide range of instruments, including larger loads of dental and medical tools, ensuring high efficiency in busy environments.\u003c\/li\u003e\n\u003cli\u003eQ: What is the cycle time for the Tuttnauer 3870HSG-WS Autoclave?\u003cbr\u003eA: The cycle time varies based on the selected program and load, but typically, a full sterilization cycle ranges between 30-60 minutes, depending on the size of the load and specific settings.\u003c\/li\u003e\n\u003cli\u003eQ: Is the Tuttnauer 3870HSG-WS suitable for medical and dental instruments?\u003cbr\u003eA: Yes, the Tuttnauer 3870HSG-WS is specifically designed for use in medical and dental environments, capable of sterilizing various instruments, including handpieces, surgical tools, and other equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDaily Cleaning: Clean the interior chamber, door, and exterior of the autoclave after each use. Use a damp cloth and mild detergent to remove any residues. Avoid harsh chemicals that could damage the surfaces.\u003c\/li\u003e\n\u003cli\u003eCheck and Replace Gaskets: Inspect the door gasket regularly for signs of wear, damage, or cracks. Replace it immediately if necessary to ensure a proper seal during the vacuum and sterilization process.\u003c\/li\u003e\n\u003cli\u003eClean the Filters: Check and clean the air and water filters regularly to maintain proper air circulation and water quality. Replace filters as per the manufacturer's recommendations.\u003c\/li\u003e\n\u003cli\u003eDrain Water Reservoir: After each cycle, drain the water reservoir and refill it with clean distilled or demineralized water. This helps prevent mineral buildup and ensures optimal sterilization performance.\u003c\/li\u003e\n\u003cli\u003eDescaling: If you are using hard water, periodically descale the system to prevent mineral deposits from clogging the pipes and affecting the performance. Use a recommended descaling solution. \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Tuttnauer","offers":[{"title":"Default Title","offer_id":46503624114401,"sku":"TTN-3870HSG-WS-230-D","price":23504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/tuttnauer-3870hsg-ws-pre-and-post-vacuum-autoclave_ad713e22-5e1c-4ab5-b5ed-e316840598a8_grande_11.jpg?v=1748339991","url":"https:\/\/sportsteez.com\/products\/tuttnauer-3870hsg-ws-pre-and-post-vacuum-autoclave-ttn-3870hsg-ws-230-d","provider":"EP","version":"1.0","type":"link"}