{"product_id":"tuttnauer-bionova-incubator-ttn-wtl198-0079","title":"Tuttnauer Bionova Incubator -  TTN-WTL198-0079","description":"\u003cdiv class=\"accordion-single js-acc-single\" id=\"Description\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item is-open\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003ch2\u003eTuttnauer Bionova Incubator -  TTN-WTL198-0079\u003c\/h2\u003e\n\u003cp\u003eThe Tuttnauer Bionova Incubator (#WTL198-0079) can test Biological Indicators for the presence of bacteria after a sterilization procedure.\u003c\/p\u003e\n\u003cp\u003eThe Tuttnauer Bionova Incubator is a large biological reader that can hold up to 12 biological indicator vials. It can implement two simultaneous programs in the chamber, with up to six indicators for each program. This reader device is compatible with Rapid, Super Rapid, and Ultra Rapid Biological Indicators. For Rapid Biological Indicators, analysis can complete in as little as one hour or up to four hours, depending on the model of the indicator. The Super Rapid Biological Indicators can complete in 30 minutes to one hour. The Ultra Rapid Biological Indicators are the fastest, at a complete analysis within 20 minutes.\u003c\/p\u003e\n\u003cp\u003eWith the advantage of two incubation programs running simultaneously, lab technicians can quickly determine if large loads of sterilized equipment have been completely sterilized and are safe to use. With 12 slots for biological indicators, users can test multiple loads of sterilized equipment to verify the effectiveness of the sterility. The device alerts technicians with a green or red light: green for a successful sterilization, and red for if microorganisms were detected after sterilization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Features\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eFeatures\u003c\/h5\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cul\u003e\n\u003cli\u003eCan incubate up to 12 biological indicators at once.\u003c\/li\u003e\n\u003cli\u003eIncludes printer for instant results for analysis.\u003c\/li\u003e\n\u003cli\u003eSupports Rapid, Super Rapid, and Ultra Rapid Biological Indicators.\u003c\/li\u003e\n\u003cli\u003eColored lights indicate whether sterilization failed or was a success.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eSpecifications\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Specifications\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eDimensions\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003e7\" height x 10.2\" diameter (18 cm x 26 cm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e4.2 lb (1.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eShelf Life\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCurrent\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0.2 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eVoltage (DC)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e12 DC Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCurrent (DC)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e4 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eAltitude\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e3500 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e50° - 86° F (10° - 30° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e30 - 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInstallation\/Overvoltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCategory II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eDegree of Contamination\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e50° - 86° F (10° - 30° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Accessories\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eAccessories\u003c\/h5\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e#WTL198-0147:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eTuttnauer Thermometer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#WTL198-0058:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eTuttnauer Rapid Biological Indicator - 1 Hour (50\/Box).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#WTL198-0072:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eTuttnauer Ultra Rapid Biological Indicator - 20 Minutes (50\/Box).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#WTL198-0075:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eTuttnauer Process Challenge Device - 1 Hour (25\/Box).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e#WTL198-0077: \u003c\/b\u003eTuttnauer Process Challenge Device - 25 Minutes (25\/Box).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accordion-single js-acc-single\" id=\"Literature\"\u003e\n\u003cdiv class=\"accordion-single-item js-acc-item\"\u003e\n\u003ch5 class=\"accordion-single-title js-acc-single-trigger\"\u003eLiterature\u003c\/h5\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"accordion-single-inner--content\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1046\/1086\/files\/Tuttnauer-Biological-Indicators-What-to-Know.pdf?\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\" target=\"_blank\"\u003eTuttnauer Biological Indicators - What to Know\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"30\" data-end=\"179\"\u003e\n\u003cstrong data-start=\"32\" data-end=\"64\"\u003eAdvanced Temperature Control\u003c\/strong\u003e – Provides precise temperature regulation for consistent incubation, essential for sensitive biological samples.\u003c\/li\u003e\n\u003cli data-start=\"180\" data-end=\"319\"\u003e\n\u003cstrong data-start=\"182\" data-end=\"203\"\u003eSpacious Interior\u003c\/strong\u003e – Offers ample space for multiple cultures or samples, making it ideal for laboratories and medical environments.\u003c\/li\u003e\n\u003cli data-start=\"320\" data-end=\"434\"\u003e\n\u003cstrong data-start=\"322\" data-end=\"346\"\u003eReliable Performance\u003c\/strong\u003e – Built with high-quality materials to ensure durability and long-term functionality.\u003c\/li\u003e\n\u003cli data-start=\"435\" data-end=\"549\"\u003e\n\u003cstrong data-start=\"437\" data-end=\"464\"\u003eUser-Friendly Interface\u003c\/strong\u003e – Simple controls for easy operation and monitoring, even in high-demand settings.\u003c\/li\u003e\n\u003cli data-start=\"550\" data-end=\"679\"\u003e\n\u003cstrong data-start=\"552\" data-end=\"572\"\u003eEnergy-Efficient\u003c\/strong\u003e – Designed to minimize energy consumption while maintaining stable conditions for optimal sample growth.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"0\" data-end=\"260\"\u003e\u003cstrong data-start=\"0\" data-end=\"62\"\u003eQ: What is the purpose of the Tuttnauer Bionova Incubator?\u003c\/strong\u003e\u003cbr data-start=\"62\" data-end=\"65\"\u003eA: The Tuttnauer Bionova Incubator is designed to provide a stable environment for growing cultures and biological samples, ensuring precise temperature control for optimal incubation conditions.\u003c\/p\u003e\n\u003cp data-start=\"262\" data-end=\"490\"\u003e\u003cstrong data-start=\"262\" data-end=\"324\"\u003eQ: What is the temperature range of the Bionova Incubator?\u003c\/strong\u003e\u003cbr data-start=\"324\" data-end=\"327\"\u003eA: The Bionova Incubator offers a precise temperature range, typically from 5°C above ambient to 65°C, suitable for various biological and laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"492\" data-end=\"729\"\u003e\u003cstrong data-start=\"492\" data-end=\"569\"\u003eQ: Is the Tuttnauer Bionova Incubator suitable for all types of cultures?\u003c\/strong\u003e\u003cbr data-start=\"569\" data-end=\"572\"\u003eA: Yes, it is designed to support a wide range of biological cultures and samples, making it ideal for use in medical, pharmaceutical, and research settings.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"946\"\u003e\u003cstrong data-start=\"731\" data-end=\"796\"\u003eQ: How is the temperature regulated in the Bionova Incubator?\u003c\/strong\u003e\u003cbr data-start=\"796\" data-end=\"799\"\u003eA: The incubator features advanced temperature control technology that ensures accurate and consistent conditions throughout the incubation period.\u003c\/p\u003e\n\u003cp data-start=\"948\" data-end=\"1176\"\u003e\u003cstrong data-start=\"948\" data-end=\"1008\"\u003eQ: What safety features does the Bionova Incubator have?\u003c\/strong\u003e\u003cbr data-start=\"1008\" data-end=\"1011\"\u003eA: The Bionova Incubator is equipped with over-temperature protection, ensuring safety and preventing overheating, along with a reliable, easy-to-use control system.\u003c\/p\u003e\n\u003cp data-start=\"1178\" data-end=\"1400\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"1178\" data-end=\"1229\"\u003eQ: How should I maintain the Bionova Incubator?\u003c\/strong\u003e\u003cbr data-start=\"1229\" data-end=\"1232\"\u003eA: Regular cleaning, calibration, and monitoring of temperature settings will help ensure the incubator remains in optimal working condition for consistent performance.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"73\" data-end=\"242\"\u003e\n\u003cstrong data-start=\"76\" data-end=\"101\"\u003eClean After Each Use:\u003c\/strong\u003e Wipe the interior and exterior surfaces of the incubator regularly to remove dirt, dust, or spills, using a mild detergent and a soft cloth.\u003c\/li\u003e\n\u003cli data-start=\"243\" data-end=\"411\"\u003e\n\u003cstrong data-start=\"246\" data-end=\"281\"\u003eCheck Temperature and Humidity:\u003c\/strong\u003e Regularly monitor the temperature and humidity levels to ensure they remain within the recommended range for optimal performance.\u003c\/li\u003e\n\u003cli data-start=\"412\" data-end=\"539\"\u003e\n\u003cstrong data-start=\"415\" data-end=\"433\"\u003eInspect Seals:\u003c\/strong\u003e Check door seals for wear or damage, and replace if necessary to maintain consistent internal conditions.\u003c\/li\u003e\n\u003cli data-start=\"540\" data-end=\"678\"\u003e\n\u003cstrong data-start=\"543\" data-end=\"569\"\u003eClean the Air Filters:\u003c\/strong\u003e Regularly clean or replace the air filters to ensure proper airflow and maintain the incubator’s efficiency.\u003c\/li\u003e\n\u003cli data-start=\"679\" data-end=\"815\"\u003e\n\u003cstrong data-start=\"682\" data-end=\"704\"\u003eCalibrate Sensors:\u003c\/strong\u003e Periodically calibrate temperature and humidity sensors to ensure accurate readings and consistent conditions.\u003c\/li\u003e\n\u003cli data-start=\"816\" data-end=\"975\"\u003e\n\u003cstrong data-start=\"819\" data-end=\"842\"\u003eInspect for Damage:\u003c\/strong\u003e Check the incubator for any signs of wear or damage, especially electrical components or connections, and perform repairs as needed.\u003c\/li\u003e\n\u003cli data-start=\"976\" data-end=\"1123\"\u003e\n\u003cstrong data-start=\"979\" data-end=\"1012\"\u003eCheck for Proper Ventilation:\u003c\/strong\u003e Ensure that vents are clear of obstructions and working correctly to allow for proper airflow and circulation.\u003c\/li\u003e\n\u003cli data-start=\"1124\" data-end=\"1241\"\u003e\n\u003cstrong data-start=\"1127\" data-end=\"1151\"\u003ePrevent Overloading:\u003c\/strong\u003e Avoid overcrowding the incubator to maintain proper airflow and temperature distribution.\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1382\"\u003e\n\u003cstrong data-start=\"1245\" data-end=\"1275\"\u003ePower Off When Not in Use:\u003c\/strong\u003e If the incubator is not in use for an extended period, turn it off and clean it thoroughly before storing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tuttnauer","offers":[{"title":"Default Title","offer_id":46503608090849,"sku":"TTN-WTL198-0079","price":1266.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/tuttnauer-bionova-incubator_11_6bcbefab-cc03-4a14-9b92-25314ef900b9.jpg?v=1748339231","url":"https:\/\/sportsteez.com\/products\/tuttnauer-bionova-incubator-ttn-wtl198-0079","provider":"EP","version":"1.0","type":"link"}