{"product_id":"tuttnauer-tvet-9m-manual-autoclave-ttn-tvet-9m","title":"Tuttnauer tvet 9M Manual Autoclave - TTN-TVET-9M","description":"\u003ch2\u003eTuttnauer tvet 9M Manual Autoclave - TTN-TVET-9M\u003c\/h2\u003e\n\u003cp\u003eThe Tuttnauer tvet 9M Manual Autoclave (TVET 9M) is a manual autoclave intended for Veterinary use.\u003c\/p\u003e\n\u003cp\u003eThis autoclave has a stainless steel chamber and door that measures 9\" x 18\", and can house three trays of instruments. There's a drain valve located at the front, which makes it easy to drain the water reservoir. As for safety features, there's a dual safety thermostat to prevent overheating, and a double safety locking device that keeps the door closed while pressurized. When a cycle is finished, the autoclave will automatically shut off.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFront drain valve for easy water removal.\u003c\/li\u003e\n\u003cli\u003eDual safety thermostats prevents overheating.\u003c\/li\u003e\n\u003cli\u003eDual safety locks prevent door opening while pressurized or in operation.\u003c\/li\u003e\n\u003cli\u003eStainless chamber and door ensure long life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-gvcd{background-color:#ffffff;border-color:#000000;color:#000000;text-align:left;vertical-align:top}\n.tg .tg-oevy{background-color:#ffffff;border-color:#000000;color:#000000;font-weight:bold;text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-oevy\"\u003eChamber Dimensions\u003c\/th\u003e\n\u003cth class=\"tg-gvcd\"\u003e9\" x 18\" (230 mm x 470 mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eVolume\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e5 gallons (19 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e21.5\" x 20\" x 14.4\" (545 mm x 510 mm x 365 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eTotal Volume\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e9 cubic feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eStandard Cassette Capacity\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e2 Full (8\" x 11\") and 2 Half (8\" x 5.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eTray Dimensions\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e16.3\" x 6.7\" x 0.8\" (415 mm x 170 mm x 20 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eNo. of Trays\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eStandard Unwrapped Cycle\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003eSterilization: 4 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eDrying: 1 min\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e42192211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eTotal: 20 min\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e400 lbs. Weight Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eStandard Wrapped Cycle\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003eSterilization: 7 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eDrying: 45 min\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eTotal: 65 min\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eVoltage and Frequency\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e120 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e1400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eCurrent\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-oevy\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd class=\"tg-gvcd\"\u003e85 lb (39 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eManual Operation – Simple, hands-on controls provide precise sterilization, making it ideal for small to medium-sized practices.\u003c\/li\u003e\n\u003cli\u003eEfficient Sterilization – Delivers consistent results with effective steam sterilization, perfect for veterinary and dental instruments.\u003c\/li\u003e\n\u003cli\u003eCompact \u0026amp; Durable – Designed for space efficiency without compromising on strength, built to last in demanding environments.\u003c\/li\u003e\n\u003cli\u003eReliable Performance – Operates with a proven track record of reliability and longevity, ensuring peace of mind.\u003c\/li\u003e\n\u003cli\u003eCost-Effective – An excellent solution for those seeking a reliable, budget-friendly autoclave without sacrificing performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the Tuttnauer TVET 9M Manual Autoclave?\u003c\/strong\u003e\u003cbr\u003eA: The Tuttnauer TVET 9M Manual Autoclave is designed for efficient sterilization of instruments in veterinary, dental, and laboratory environments, providing a reliable and cost-effective solution for smaller practices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the manual operation of the TVET 9M Autoclave work?\u003c\/strong\u003e\u003cbr\u003eA: The TVET 9M features manual controls, allowing the operator to adjust the cycle parameters for sterilization, offering flexibility and ease of use for various sterilization needs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the capacity of the Tuttnauer TVET 9M Manual Autoclave?\u003c\/strong\u003e\u003cbr\u003eA: The TVET 9M has a chamber capacity of 9 liters, making it suitable for sterilizing a moderate load of instruments and providing efficient sterilization in smaller settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of items can be sterilized with the TVET 9M Autoclave?\u003c\/strong\u003e\u003cbr\u003eA: The autoclave is ideal for sterilizing surgical instruments, dental tools, glassware, and other items that require high-heat sterilization in veterinary and laboratory environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What safety features does the TVET 9M include?\u003c\/strong\u003e\u003cbr\u003eA: The autoclave comes with built-in safety features such as automatic pressure control, a safety valve, and a door lock during the sterilization cycle, ensuring safe operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should I maintain the Tuttnauer TVET 9M Manual Autoclave?\u003c\/strong\u003e\u003cbr\u003eA: Regular cleaning, using distilled water, and performing scheduled maintenance checks will ensure optimal performance and extend the lifespan of the autoclave.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eClean After Each Use: Wipe down the exterior and interior chamber with a soft, damp cloth to remove any residue or moisture. Use mild detergents to avoid damaging surfaces.\u003c\/li\u003e\n\u003cli\u003eInspect Door Seals and Gasket: Regularly inspect the door seals and gaskets for signs of wear or damage. Replace them if they appear cracked or worn to maintain airtight sealing.\u003c\/li\u003e\n\u003cli\u003eDrain After Use: Always drain the water reservoir after each cycle to prevent the buildup of mineral deposits or stagnant water.\u003c\/li\u003e\n\u003cli\u003eCheck and Clean Filters: Periodically clean or replace the filters to ensure proper air and steam circulation and prevent blockages.\u003c\/li\u003e\n\u003cli\u003eCalibrate the Temperature and Pressure: Ensure the temperature and pressure gauges are accurate by calibrating them regularly. This ensures reliable sterilization cycles.\u003c\/li\u003e\n\u003cli\u003eTest the Safety Valve: Perform safety valve tests periodically to make sure that the valve is functioning correctly and releasing pressure when necessary.\u003c\/li\u003e\n\u003cli\u003eInspect the Heating Element: Check the heating element for signs of wear, damage, or mineral buildup. Clean it periodically to ensure optimal performance.\u003c\/li\u003e\n\u003cli\u003eLubricate Moving Parts: Apply lubricant to any moving parts like the door latch mechanism to maintain smooth operation.\u003c\/li\u003e\n\u003cli\u003ePerform Regular Professional Service: Schedule routine servicing by a qualified technician for deep cleaning, system checks, and preventive maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Tuttnauer","offers":[{"title":"Default Title","offer_id":46503610515681,"sku":"TTN-TVET-9M","price":3540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/9776\/9953\/files\/tuttnauer-tvet-9m-manual-autoclave_fe1f724a-7f36-402c-9494-d82b5f9b063a_grande_11.jpg?v=1748339325","url":"https:\/\/sportsteez.com\/products\/tuttnauer-tvet-9m-manual-autoclave-ttn-tvet-9m","provider":"EP","version":"1.0","type":"link"}